6. EXAMPLE OF APPLICATION FOR SECTIONAL OVERHEAD DOORS
Fig. 6.1
Fig. 6.2
(Fig. 6.1) When the control panel is used in applications for
sectional automations:
- set DIP1=ON;
- set DIP2=ON;
- set DIP4=OFF;
- connect opening and closing limit switches N.C. contacts to
terminals 0-11-12;
Note: to use the electronic control panel in hold-to-run mode,
disconnect terminal 9.
In this case, the opening (1-3, 1-20) and the closing (1-4) con-
trols operate only if kept pressed, if released the automation
will stop.
Automatic closing and radio remote controls are disabled.
(Fig. 6.2) If the self-controlled safety edge SOFA1 - SOFA2 is
connected in closure, make the connections indicated in the
diagram.
Warning: if the closing edge remains pressed on the floor, cut
the jumper SO.
Note: push-button panels PT3 (fig. 6.1) or PT4 (fig. 6.2) can be
connected to the connector J7.