ESIM022 User manual v1.1
Set input as NO
(normally open)
SMS
SMS text message content:
ZONE1:NO
Example:
ZONE1:NO
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
View input state
SMS
SMS text message content:
STATUS
Example:
STATUS
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
View real-time
input voltage
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
View input
parameters
Config
Tool
This operation may be carried out from the PC using the
ELDES Configuration Tool
software.
For more details on how to manage the alarm/restore notifications, please refer to
10 ALARM/
RESTORE NOTIFICATIONS.
For more details on how to view system’s information that may include input state, please refer to
13. SYSTEM INFORMATION. STATUS SMS.
8.2. Input Z2
Input Z2 can operate in one of the following modes at a time:
•
Digital
– The system monitors the input voltage resulting in the input state change. Nor-
mally, this mode is used for PGM output connection of non-GSM alarm system, motion de-
tectors, door contacts and other active or passive digital level sensors. This mode is set by
default. For more details on how to manage the Digital mode, please refer to
8.2.1. Digital
Mode.
•
Temperature Sensor
– The input converts to 1-Wire interface for temperature sensor
connection. For more details on how to manage the Temperature Sensor mode, please re-
fer to
8.2.2. Temperature Sensor Mode.