background image

ESIM022

GSM DIALLER

Тел:     +7 495 7907870

Моб:   +7 965 4429948 

Skype:  Discoverytelecom 

Mail:     [email protected] 

www.discoverytelecom.ru

Summary of Contents for ESIM002

Page 1: ...ESIM022 GSM DIALLER Тел 7 495 7907870 Моб 7 965 4429948 Skype Discoverytelecom Mail info discoverytelecom ru www discoverytelecom ru ...

Page 2: ...o be powered by an EN 60950 1 approved supply When con necting the power supply to the system mind the polarity terminals DO NOT switch the polarity terminals places External power supply must be reachable and can be connected to AC mains only inside installation room with automatic 2 pole circuit breaker capable of discon necting circuit in the event of short circuit or over current condition Ope...

Page 3: ...er for the device configuration it must earthed The WEEE Waste Electrical and Electronic Equipment marking on this product see right or its documentation indicates that the product must not be disposed of together with household waste To prevent possible harm to human health and or the environment the product must be disposed on in an approved and environmentally safe recycling process For further...

Page 4: ...AND TIME 16 8 INPUTS 17 8 1 Input Z1 17 8 2 Input Z2 18 9 TAMPER 24 10 ALARM RESTORE NOTIFICATIONS 25 11 OUTPUT 31 11 1 Output Name 31 11 2 Turning Output ON and OFF 32 12 BACK UP BATTERY AND MAINS POWER SUPPLY STATUS MONITORING 33 13 SYSTEM INFORMATION STATUS SMS 37 13 1 Periodic Status SMS 38 14 SYSTEM NOTIFICATIONS 39 15 ON BOARD TEMPERATURE SENSOR 43 16 REMOTE LISTENING 44 17 TECHNICAL SUPPORT...

Page 5: ...5 5 ESIM022 User manual v1 1 Тел 7 495 7907870 Моб 7 965 4429948 Skype Discoverytelecom Mail info discoverytelecom ru www discoverytelecom ru ...

Page 6: ... guidelines outlined in this manual and in accordance with the operating conditions specified The warranty is void if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environments or force majeure factors Dear Customer Thank you for choosing to purchase the GSM dialler ESIM022 Your thoughtful decision will ensure reliable solution for many yea...

Page 7: ...oration of an electronic device by SMS text message or phone call Main features Configuration by SMS text message and PC Up to 2 users for system configuration control and acceptance of system event notifications by SMS text messages or phone calls 2 inputs customizable as NC or NO Input Z1 mode digital Input Z2 modes digital or temperature sensor for 1 external temperature sensor connection 1 ope...

Page 8: ...1 Output circuit Open collector output Output is pulled to COM when turned ON Maximum commuting output values 30 V 200 mA Number of inputs 2 Supported temperature sensor model Maxim Dallas DS18S20 DS18B20 PCB dimensions 71x50x27 mm Enclosure dimensions 96x59x34 mm Operating temperature range 30 55 C 35 55 C with limitations Humidity 0 90 RH 0 40 C non condensing 2 2 Main Unit LED Indicator Connect...

Page 9: ...nector Backup battery slots F1 0 5A fuse LED indication Description OFF No power supply Flashing every 30 ms SIM card is not present PIN code enabled Flashing every 0 5 sec Searching for GSM network Flashing every 1 sec Connected to GSM network system operating successfully Connerctors Description Z1 Digital input terminal COM Common terminal Z2 Digital input terminal temperature sensor data termi...

Page 10: ... sensor wiring ESIM022 Alarm system or other appliance 12V PGM2 PGM1 Z1 Z2 COM COM DC C1 ESIM022 DS18S20 DS18B20 Temperature sensor COM Z1 Z2 DC C1 COM GND GND DATA DATA 4V 4V Output wiring ESIM022 Alarm system or other appliance 12 V Electrical appliance COM Z1 Z2 DC C1 COM 3 4 5 ...

Page 11: ...closer than 20 cm to the metal surface and or power lines 3 Disable the PIN code request of the SIM card by inserting it into a mobile phone and following the proper menu steps 4 Once the PIN code is disabled insert the SIM card into the SIM card slot holder of ESIM022 system 8 OPEN 7 9 10 5 If you have obtained a back up battery with your system insert it into the battery slots Take care when con...

Page 12: ...vices that might cause incorrect sys tem operation Please contact your GSM operator for more details on these services and how to disable them NOTE For maximum system reliability we recommend you do NOT use a Pay As You Go SIM card Otherwise in the event of insufficient credit balance on the SIM card the system would fail to make a phone call or send SMS text messages NOTE We advise you to choose ...

Page 13: ...ho ne call regarding system alarm restore arming disarming and other events depending on alarm system configuration In addition to being informed by SMS text message or phone call regarding alarm and restore events of the inputs the users can control one electrical appliance by connec ting it to the open collector output For example users can turn ON or OFF the heating lighting lift the gates blin...

Page 14: ...iguration process by allowing to use a personal computer in the process Before starting to use EL DES Configuration Tool software please read the user guide provided in the soft ware s HELP section NOTE Configuration by USB cable and ELDES Configuration Tool software does not require the external power supply to be connected and or back up battery to be inserted in the device 6 USER PHONE NUMBERS ...

Page 15: ...mber of the system for the first time the system will reject the phone call and au tomatically set up the phone number as User 1 phone number that the phone call has been made from This feature DOES NOT apply to User 2 phone number Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View user phone number Config Tool This operation may be carried o...

Page 16: ...MS SMS text message content CLK yyyy mm dd_hr mn Value yyyy year mm month range 01 12 dd day range 01 31 hr hours range 00 23 mn minutes range 00 59 Example CLK 2013 03 16_14 33 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View date and time SMS SMS text message content STATUS Example STATUS Config Tool This operation may be carried out from...

Page 17: ...for input Z1 a Monitors input voltage ranging from 0 mV through 3000 mV every 100 millisecond b Verifies if the set up threshold by default 1500 mV is not exceeded c By default the input is set as NO normally open therefore if the voltage drops below the threshold it will result in input state change to alarm followed by notifying the user by SMS text message and or phone call d When the voltage r...

Page 18: ...ils on how to manage the alarm restore notifications please refer to 10 ALARM RESTORE NOTIFICATIONS For more details on how to view system s information that may include input state please refer to 13 SYSTEM INFORMATION STATUS SMS 8 2 Input Z2 Input Z2 can operate in one of the following modes at a time Digital The system monitors the input voltage resulting in the input state change Nor mally thi...

Page 19: ... from the PC using the ELDES Configuration Tool software 8 2 1 Digital Mode When Digital mode is set the system follows this pattern a Monitors input voltage ranging from 0 mV through 3000 mV every 100 millisecond b Verifies if the set up threshold by default 1500 mV is not exceeded c By default the input is set as NO normally open therefore if the voltage drops below the threshold it will result ...

Page 20: ... may be carried out from the PC using the ELDES Configuration Tool software Set input as NO normally open SMS SMS text message content ZONE2 NO Example ZONE2 NO Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View input state SMS SMS text message content STATUS Example STATUS Config Tool This operation may be carried out from the PC using the E...

Page 21: ...ery 60 minutes To set a different temperature update period please refer to the following configuration methods Set temperature update period SMS SMS text message content PTEMP temp per Value temp per temperature update period range 3 71000000 minutes Example PTEMP 45 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Adding Removing and Replacing...

Page 22: ...n may be carried out from the PC using the ELDES Configuration Tool software Temperature Info SMS The system supports an SMS text message identified as the Temperature Info SMS which is auto matically delivered to the preset user phone number if the minimum MIN by default 20 C or maximum MAX by default 30 C temperature threshold of the external temperature sensor is exceeded Optionally a name for ...

Page 23: ...nd MAX thresholds Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View temperature sensor name and temperature value SMS SMS text message content STATUS Example STATUS Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software To stop Temperature Info SMS sending please disable the temperature sensor T...

Page 24: ...e refer to 14 SYSTEM NOTIFICATIONS 9 TAMPER The system comes equipped with on board tamper switch designed for sabotage detection In the event of enclosure tampering the system can notify the user by SMS text message or phone call For more details on tamper alarm restore notification management please refer to 10 ALARM RESTORE NOTIFICATIONS To set a tamper name that is included in the tamper alarm...

Page 25: ...LDES Configuration Tool software SMS By default in the event of tamper or input alarm or restore the system will follow this pattern a The system attempts to send an SMS text message containing input alarm restore text to the first preset user phone number only b If the user phone number is unavailable and the system fails to receive the SMS delivery report within 20 seconds it will attempt to sen...

Page 26: ...AZi ON Value i input number range 1 2 Example SAZ2 ON Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Set input alarm text SMS SMS text message content TAZi in alarm text Value i input number range 1 2 in alarm text up to 23 characters input alarm text Example TAZ2 Alarm Z2 Config Tool This operation may be carried out from the PC using the ELD...

Page 27: ... re text up to 23 characters input restore text Example TRZ1 Restore Z1 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Disable tamper alarm restore notification SMS SMS text message content TMP OFF Example TMP OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Enable tamper alarm restore n...

Page 28: ...ing the first preset user phone number b When the call is answered the user will be able to listen on the mobile phone for 60 seconds to what is happening in the area surrounding the system see 16 REMOTE LISTENING c The system will dial the next preset user phone number if the previous user was unavailable due to the following reasons mobile phone has been switched off mobile phone has been out of...

Page 29: ...f input alarm SMS SMS text message content CAZi OFF Value i input number range 1 2 Example CAZ2 OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Enable call in the event of tamper alarm SMS SMS text message content TMP ON Example TMP ON Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Disa...

Page 30: ... Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software ATTENTION Inputalarm restorenotificationsdoNOTapplywheninputZ2issetuptooperatein Temperature Sensor mode For more details please refer to 8 2 2 Temperature Sensor Mode ...

Page 31: ... to wire the output please refer to 2 3 Wiring Diagrams 11 1 Output Name The output has a name that can be customized by the user Typically the name specifies a device type connected to the output for example Lights By default output C1 name is Output To rename the output please refer to the following config uration methods Rename output SMS SMS text message content TOUT out name Value out name up...

Page 32: ...l software Turn OFF output SMS SMS text message content OUT OFF Example OUT OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View output status SMS SMS text message content STATUS Example STATUS Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software NOTE The output status on system start up is a...

Page 33: ...e is 8V or lower By default the notifications regarding the back up battery status are disabled To enable disable a certain notification please refer to the following configuration methods Enable Battery Connected notification SMS SMS text message content BATCON ON Example BATCON ON Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Set Battery Cc...

Page 34: ...Configuration Tool software Disable Battery Disconnected notification SMS SMS text message content BATDIS OFF Example BATDIS OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Enable Low Battery notification SMS SMS text message content BLOW ON Example BLOW ON Config Tool This operation may be carried out from the PC using the ELDES Configurat...

Page 35: ...fault system notification by SMS text message regarding mains power supply status is disa ble To enable disable a certain notification please refer to the following configuration methods Enable Mains Power Supply Lost notification SMS SMS text message content PWRLOST ON Example PWRLOST ON Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Set Main...

Page 36: ...text Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Disable Mains Power Supply Restore notification SMS SMS text message content PWRREST OFF Example PWRREST OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View Back up Battery and Mains Power Supply notification parameters Config Tool Th...

Page 37: ... be carried out from the PC using the ELDES Configuration Tool software By default the aforementioned items except System name are excluded from the Status SMS To include them please refer to the following configuration method Manage Status SMS content SMS SMS text message content TESTM 1 2 4 5 6 7 8 Value 1 system name 2 system date and time 4 GSM signal strength 5 system s internal tempera ture ...

Page 38: ...e periodic Status SMS and set frequency SMS SMS text message content TEST frequen Value frequen frequency range 1 1193046 hours Example TEST 15550 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Disable periodic Status SMS SMS SMS text message content TEST OFF Example TEST OFF Config Tool This operation may be carried out from the PC using the ...

Page 39: ...ls on how to manage this notification please refer to the configuraition methods below 2 Input Alarm SMS text message sent to the user in case input Z1 or Z2 is violated For more details on how to manage this notification please refer to 10 ALARM RESTORE NOTIFICATIONS 3 Input Restore SMS text message sent to the user in case input Z1 or Z2 is restored For more details on how to manage this notific...

Page 40: ...message sent to the user in case the battery level reaches the set up minimum value For more details on how to manage this notification please refer to 12 BACK UP BAT TERY AND MAINS POWER SUPPLY STATUS MONITORING 12 Device Shutdown When the system is running on backup battery power it sends the SMS text message when backup battery voltage reaches 7 8V before it is fully depleted For more details o...

Page 41: ...e Disable Device Started notification SMS SMS text message content SSMS OFF Example SSMS OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software By default System Shutdown notification is disabled To enable disable it and set the text for this notification please refer to the following configuration methods Enable Device Shutdown notification SMS S...

Page 42: ...iguration Tool software View system notification parameters Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software ATTENTION Colon dash commacharactersareNOTallowedinDeviceStartedandDeviceShut down notification text For more details on how the system notifies the user in the event of input or tamper alarm re store please refer to 10 ALARM RESTORE NOTI...

Page 43: ...ure SMS to the preset user phone number To enable disable the on board temperature sensor as well as to set and view the MIN MAX tem perature thresholds please refer to the following configuration methods Disable enble on board temperature sensor Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software Set MIN and MAX thresholds Config Tool This operati...

Page 44: ...n will last for up to 60 seconds until the system automatically hangs up By default when the preset user dials the system phone number the system automatically an swers the call This feature is identified as Answer Call To disable enable the Answer Call feature and set a different microphone gain by default 12 please refer to the following configuration methods Disable Answer Call feature SMS SMS ...

Page 45: ... Value mg microphone gain range 1 15 Example MIC 10 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software View remote listening parameters Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software ...

Page 46: ... to receive any SMS text mes sage reply to the user phone number and control the device Insufficient SIM card credit balance No GSM network signal Wrong user phone number User phone number is not set Received SMS text message Wrong syntax Incorrect SMS text message structure Unnecessary space character might have been typed in SMS text message 17 2 Restoring Default Parameters 1 Disconnect the pow...

Page 47: ...ble to the PC 4 The new window must pop up where you will find the bin file Otherwise open My Computer and look for CRP DISABLED drive 5 Delete the bin file found in the drive 6 Copy the new firmware bin file to the very same window 7 Unplug USB cable 8 Remove short circuit from FW pins 9 Firmware updated NOTE It is strongly recommended to restore default parameters after the firmware update ...

Page 48: ...ESIM022 User manual v1 1 18 RELATED PRODUCTS DC power supply DS18S20 temperature sensor Microphone Тел 7 495 7907870 Моб 7 965 4429948 Skype Discoverytelecom Mail info discoverytelecom ru www discoverytelecom ru ...

Reviews: