6
2.2 Mechanical Specifications
Table 2-2.
DLP-GC2 Mechanical Specifications
Mechanical Spec.
DLP-GC2-12V
DLP-GC2-24V
DLP-GC2-36V
DLP-GC2-48V
Chemistry
LiFePO
4
Length
260 mm (10.2 in)
Width
180 mm (7.1 in)
Total Height
275 mm (10.8 in)
Terminal
5/16 in Stud (Height 22 mm)
5/16 in Button Insert (Depth 18 mm)
Terminal Torque
13 Nm 9.6 ft-lb
Weight
14.0 kg (30.7 lb)
14.0 kg (30.7 lb)
11.2 kg (24.7 lb)
14.0 kg (30.7 lb)
IP Rating
IP 67
Case Material
UL94-VO PBT/PC
2.3 Environmental Specifications
Table 2-3.
DLP-GC2 Environmental Specifications
Environmental Spec.
All Models
Charge Temperature
a,b
-20°C to 55°C (-4°F to 131°F)
Discharge Temperature
a
-20°C to 60°C (-4°F to 140°F)
Storage Temperature (1 month)
c
-20°C to 45°C (-4°F to 113°F)
Storage Temperature (6 months)
c
-10°C to 30°C (14°F to 86°F)
a
This is the specified temperature of the cells and not ambient. Ambient temperature and cell temperature may not
be the same.
b
The Battery Management System will not allow charging of the cells below 0°C. When charge begins below 0°C, the
energy is diverted to the internal heating until the cells reach 2°C, at which time cells will begin to be charged.
c
Storage outside of specified temperatures will result in permanent capacity loss and invalidate the warranty.
2.4 Protection Specifications
Table 2-4.
DLP-GC2 Protection Specifications
Protection Spec.
DLP-GC2-12V
DLP-GC2-24V
DLP-GC2-36V
DLP-GC2-48V
Overvoltage
Protection
a
> 14.6 V for 3s
> 29.2 V for 3s
> 43.8 V for 3s
> 58.4 V for 3s
Recovery
a
Recover after
120s and < 13.8 V
Recover after
120s and < 27.6 V
Recover after
120s and < 41.4 V
Recover after
120s and < 55.2 V
Undervoltage
Protection
b
< 10 V for 5s
< 20 V for 5s
< 30 V for 5s
< 40 V for 5s
Recovery
b
No automatic recovery. The battery will shut down after 120 seconds
Over-charge Current
Protection
> 132 A for 10s
> 66 A for 10s
> 33 A for 10s
> 33 A for 10s
Recovery
Recovery after 120 seconds.