![Discount Equipment SKYJACK SJ3013 Operation Manual Download Page 57](http://html1.mh-extra.com/html/discount-equipment/skyjack-sj3013/skyjack-sj3013_operation-manual_2508809057.webp)
236613ACA
SJ3013 & SJ3014 micro
60
Section 7 – Specifications
Environment
2078AB
Model
SJ3013 & SJ3014 micro
Electromagnetic Compatibility (EMC)
Do not use near intense electromagnetic fi elds (radar, high voltage or high
currents).
Hazardous Location Rating
The MEWP is not rated for hazardous locations with potentially fl ammable gases,
explosive gases or particles.
Operating Temperatures
-20°C (-4°F) – +40°C (+104°F)
Model
Wind rating
Total platform capacity
Extension platform
capacity
Manual side
force
Tilt cutout
setting (side-to-side x
front-to-back)
SJ3013
& SJ3014
micro
0 m/s
[0 mph]
240 kg
(529 lb)
2 Persons
100 kg
(220 lb)
1 Person
400 N
90 lbf
2.5˚ × 3.5˚
2079AB
NOTE
Occupants and materials are not to exceed the rated load. Refer to the capacity label at the entrance of the
platform and the front kick plate for more information and models equipped with options.
7.4 Environment
7.5 Maximum platform capacities (evenly distributed)