SJ3013 & SJ3014 micro
236613ACA
39
Function Tests
Section 4 – Inspections Before Operation
4.3-17 Do a test of the lowering warning
system - European (CE) models
only
1.
Squeeze and hold the
function-enable
switch.
2.
Push the
controller handle
to
raise the platform
to a height of approximately 3 to 4 m.
3.
Pull the controller handle to lower the platform.
▪
Result:
The platform starts to lower but stops
at a height of approximately 2.5 m. An alarm
makes a sound.
4.
Release the
function-enable
switch and the
controller handle
.
5.
Make sure that the area around the MEWP is
clear.
6.
Squeeze and hold the
function-enable
switch.
7.
Pull the
controller handle
to
continue to lower
the MEWP.
▪
Result:
The platform fully lowers.
4
5
1
7
3
6
2
8