Microscope
Section
This section is divided into the microscope (1) and accessories (2).
Fig. B
-
-
-
-
12
(1) Microscope
The microscope magnifies the wafer surface so that the magnified wafer surface is displayed on
the TV monitor.
Focusing is automatically achieved thanks to the auto-foucus function. The micro/macro
function is provided to permit changeover between large and small magnifications.
(2) Accessories
A micrometer type fine adjustment mechanism is used to align the microscope center line with
the blade position.
An optical fiber cord is provided to derive illumination light from the light source.
(3) Microscope
Adjustment
Procedure
1) CCD Camera Angle Adjustment
Microscope
Focus adjust
Pulse motor
CCD camera
Micro/ macro
Changeover
solenoid valve
Optical fiber
Dark/bright cylinder
Fine adjustment
Objective lens