B
-
-
-
-
20
910228
DF
D-
2
S
/8
10 Electrical System
(1) Construction
1) Overview
The electrical system consists of a power supply section, a main control section, a subcontrol
section, and an attachment section. These sections are further divided into subsections as
described below.
●
Power Supply Section
The M/C main body has a 3 -phase, 200V (5kVA) power supply. As shown in the AC power
distribution diagram in section (2)-1), 3 -phase, 200 V power and 1 -phase, 100 V power are
supplied to all units via the distribution terminal.
In each unit, DC stabilized power supplies are derived from the supplied AC power.
●
Main Control Section
The main control section is divided into a 68000 CPU control RACK unit, a monitor synthesis
unit, a hard disk unit, a floppy disk unit, an ALU unit, a focus motor driver, a setup interface,
and regulated DC power supplies for all units.
●
Sub-control Section
The sub control section of the DFD-2S/8 or DFD-2D/8 consists of control boards for the
two-axis AC servo motor and three-axis stepping motor or five-axis stepping motor, and
driver power supplies for these axes, respectively.
●
Attachment Section
This section consists of a main operation panel, a monitor, a CCD camera, a fiber light source,
a feedback unit, an axis center sensor, an inverter, a signal tower, positioning sensors,
solenoid driver units and a blade breakage detector (DFD-2D/8) (the optional a blade
breakage detector (DFD-2S/8) transformer box unit and emergency power unit may be
added).