52
InSTAllATIon InSTRuCTIonS
(wITH 2 pERSonS)
foR DIRECTTECH CRYSTAl & DIRECTTECH mIRRoR
In A plASTERBoARD CEIlInG
Installation:
1. Make the ceiling cutout in accordance with the requirements for the DIRECTTECH
heating panel. The dimensional requirements must be complied with to ensure
secure fi xation of the DIRECTTECH heating panel.
2. Fixate a wood batten (diameter= 20mm; width= min. 40mm) in the edge region of
the cutout above the plasterboard ceiling over the entire length of the long side of
the cutout (see sketch p.52). Before mounting the wood batten, the magnet plates
and the wooden eyescrews are to be mounted. The magnet plates have to be
mounted on the wood batten corresponding to the position of the already moun-
ted magnets on the frame of the DIRECTTECH heating panel (see sketch p.53). The
wooden eyescrews which serve to hold the mounting aid (ropes with carabiners)
are to be screwed in the wood batten in diagonal alignment to each other (see
sketch p.53). Screw in the eyebolts (included in delivery) in the matching square
nuts which are placed in the frame profi le at the back, in the predefi ned position
(next to the bracket) according to sketch p.53.
3. Connect the eyebolts on the DIRECTTECH heating panel with the wooden
eyescrews on the wood batten by using the ropes and carabiners (included in
delivery). This serves as mounting security and –aid.
4. The DIRECTTECH heating panel is now, secured by the ropes, in a rest position.
5. For electric installation works the regulations of the EN/VDE and the local power
supply company (EVU) are decisive.
6. After you have established the electrical connection, the DIRECTTECH heating
panel has to be inserted into the ceiling cutout according to the sketches (p.54)
and has to be slided in direction of the magnet plates until you hear a click sound
of the magnets, then the DIRECTTECH heating panel is locked in right place.
7. Ensure yourself that the magnets provide a secure and fi rm holding.
The installation is completed.
Dismantling:
1. Disconnect the electrical connections according to the safety instructions and
technical rules.
2. The dismantling takes place in reverse sequence.
3. Lift the DIRECTTECH heating panel out of the section and bring it to a rest position
(see sketches p.55).
Delivery contents:
•
1 piece DIRECTTECH heating panel
•
2 pieces eyebolts
•
2 pieces wooden eyescrews
•
2 pieces ropes with each 2 pieces carabiners (snap hooks)
Cutout dimensions for DIRECTTECH flansch heating panels:
(Installation in a plasterboard ceiling 12,5 mm)
Magnet
Magnet plate
Wooden eyescrews
Eyebolts
Plasterboard ceiling
20 mm
min. 40 mm
12,5 mm
Wood batten
SKETCH
© b
y DI
REC
TT
EC
H Global® GmbH
The installation site must provide a suffi cient carrying capacity and strength in accordance
with the weight of the product. Please hereto consult your ceiling installer/architect.
IP2001/ IP1301 / D1001
1210 x 630 mm
D701
920 x 640 mm
D501
630 x 610 mm
D431
1170 x 340 mm
Summary of Contents for Crystal D1000
Page 10: ...10...
Page 11: ...10 11...
Page 34: ...34...
Page 44: ...44...
Page 45: ...44 45...
Page 68: ...68...