40
!
!
!
Area 2
10 cm
Roof
50 cm
DIRECTTECH heating panel
10 cm
W
all
© b
y DI
REC
TT
EC
H Global® GmbH
> 180 cm!
(for panels > 100 °C)
• The distance between the installed DIRECTTECH heating panels
and wooden walls respectively infl ammable materials should at
least be 10 cm to each side and at least 50 cm to the front (see
draft).• DIRECTTECH heating panels which are directly connected
to the power supply of the building must be protected by a fuse, at
all poles, with a contact gap according to the overvoltage category
III (EN/VDE-standards).
• During the installation, please note that in accordance with the
local conditions appropriate fastening material is being used.
• Please also take notice of the local electrical regulations of electric
contractors (TAB and EN/VDE).
• To avoid possible damage to the power line, please make sure that
the power line does not touch the heating surface.
• The use of an extension cable is to be avoided. If necessary, only
use an undamaged extension cable with an adequate cable cross
section and undamaged plugs resp. couplings, to ensure the maxi-
mum device output, as well as suffi cient safety measures.
• Please check the power line regularly for damage. In case of a
damaged power line, the DIRECTTECH heating panel may not be
brought into operation. There may be the risk of an electric shock.
• Make sure that the power line is not covered by a carpet or a rug
and that its position is out of the walking route. The distance of the
DIRECTTECH heating panel to the shockproof socket outlet should
be chosen in such a way that the power line does not hang free
and tensioned (tripping hazard).
SKETCH