Your Direct Supply Panacea 1000-FLEX bed comes with a 

pendant (Figure 13).The pendant allows the patient/resident 

to operate the bed. 

 WARNING: Possible Injury or Death. 

This bed should 

not be operated (control the movements of the bed 

through the control interfaces) by persons who do not 

have the cognitive skills to understand the information in 

the owner’s manual or cannot understand and perform the 

proper operation of the bed. This bed should not be used or 

operated by children. 

Staff Control Panel Operation (Optional) 

The staff control panel (Figure 14) allows the caregivers 

to operate the bed from the foot panel without walking to 

the bedside. The caregiver can also individually lock out all 

functions, both pendant and staff control. 

1.  To lock out a function, press “Lock” graphic on the 

panel. Illuminated amber LED indicates that the 

function is now locked out. 

2.  To unlock a function, press the “Unlock” graphic 

on the panel. Amber LED is no longer illuminated, 

signaling that the function is now operable. If unlock is 

pressed all functions unlock, user may need to re-lock a 

function, if desired. 

 CAUTION: 

Be careful not to damage power cord when moving or placing bed. After placing bed in service, monitor 

power cord positioning carefully to prevent damage as you fully operate all bed functions.

 CAUTION:

 When power cord is not plugged into a wall outlet, place it on sleep surface to prevent it from contacting 

floor. This will help prevent cord damage when transporting bed.

 CAUTION: 

If a power cord is damaged, remove bed from service until repairs are performed.

 WARNING: Possible Injury

. Before leaving the bed unattended, check that the casters in the locked position. Never 

leave an unlocked bed unattended. 

 WARNING: Possible Injury.

 Check that the casters are in the locked position before allowing the resident to enter or 

exit the bed. 

Pendant Operation

Back Operation

1.  Push button to raise back

2.  Push button to lower back

Knee Operation

3.  Push button to raise knee

4.  Push button to lower knee

Auto Contour Operation

5.  Push button to raise  

back and knee

6.  Push button to lower  

back and knee

Bed Height Operation

7.  Push button to raise bed

8.  Push button to lower bed

6

5

2

1

4

3

8

7

Figure 13

Figure 15

Roll in Low Lock System

1.  To keep bed from rolling when in the lowest position, 

press down on locking lever to lock casters (Figure 15).

2.  Standard caster set comes with two locking casters 

placed at opposing corners of bed.

Mobile 
Position

Locked Position

Swivel Casters

Low 

only

Any Height (casters must 

be locked in Low)

Head & Foot (in 

Low position only)

Staff Control Operation

Back Operation

1.  Push to raise back

2.  Push to lower back

Knee Operation

3.  Push to raise knee

4.  Push to lower knee

Auto Contour Operation

5.  Push to raise back  

and knee

6.  Push to lower back  

and knee

Bed Height Operation

7.  Push to raise bed

8.  Push to lower bed

Lock Operations

9.  Push and hold to 

change lockout status. 

The Lock symbol will 

be illuminated when a 

function is locked.  

10. Push to unlock

Figure 14

Operation

 

1

2

4

6

8

3

5

7

9

9

9

10

Summary of Contents for Panacea 1000-FLEX BED

Page 1: ...uipment Furnishings Please read this entire guide carefully and keep it for future reference This guide will provide you with instructions warnings warranty informa tion and other important informatio...

Page 2: ...wall mounted outlet in good working order with no cracks or chips The plug should fit tightly into the outlet The ground pin should be intact and secure Do not use power strips extension cords or mult...

Page 3: ...tient by a qualified clinician or medical provider to ensure maximum safety of the resident patient The assessment should be conducted within the context of and in compliance with the state and federa...

Page 4: ...as should be used no closer than 30 cm 12 inches to any part of the Direct Supply Panacea 1000 FLEX bed including cables specified by the manufacturer Otherwise degradation of the performance of this...

Page 5: ...C to 70 C Relative Humidity 10 to 100 Atmospheric Pressure 500 hPa to 1060 hPa Mechanical Specifications Description Dimensions Overall Dimensions 86 9 L x 35 0 W x 8 75 H Weight Total without Panels...

Page 6: ...igure 3 2 Remove the screws using the 2 Phillips screwdriver do not discard the screws 3 Position and insert the mattress stops in the holes provided Figure 4 Reinstall the screws removed in step 2 4...

Page 7: ...soft surface front face down 3 Foot panel brackets are shorter of two sizes Figure 5 4 Install the foot panel brackets with four screws provided Bracket offset should face up Figure 6 Do not tighten...

Page 8: ...ant Route one cable under the control box and plug into pendant port Route the second cable under the control box and connect to the hand pendant Figure 9 4 Route the two cables under the main frame t...

Page 9: ...from contacting floor This will help prevent cord damage when transporting bed CAUTION If a power cord is damaged remove bed from service until repairs are performed WARNING Possible Injury Before lea...

Page 10: ...foot frame by compatible ID labels on left side Figure 16 2 Lay frame halves on soft surface feet side down Place packing material under head frame to make assembly easier Figure 17 Ensure the split f...

Page 11: ...amage to the actuators 3 Install the back actuator and knee actuator on the head frame and foot frame as shown using the actuator pin and clip Figure 19 4 Insert head frame into foot frame and line up...

Page 12: ...23 Figure 24 1 Line up back and knee actuators and insert actuator pin then add clip to lock in place Figure 22 and 23 Ensure the washers are used on the back actuator Figure 24 Figure 22 Split Frame...

Page 13: ...hen route behind cable bundle Figure 25 and 26 3 Insert back actuator cable in port 1 and insert hi lo actuator head end cable in port 3 Figure 27 4 Secure cables with cable clamp Figure 28 5 Route po...

Page 14: ...tuators and control box contain no serviceable parts Overload protection is achieved via current sensing technology which will automatically reset If any bed function fails to operate check to see if...

Page 15: ...wer cord to frame Tape remaining cables in their original position It is very important to keep actuator cables routed along frame in original factory installed positions If this step is not followed...

Page 16: ...he bed is plugged into power source and control box green light is illuminated 4 Thermal overload condition This should self correct in 2 minutes or less Do not surpass 10 duty cycle 2 min on 18 min o...

Page 17: ...yclable items properly To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources CAUTIO...

Page 18: ...to disconnect from bed resulting in loss of control of bed 4 Take extra care when moving bed remember do not move bed while occupied by resident patient on any sloped surface Moving a bed on a sloped...

Page 19: ...1 800 634 7328 for instructions 3 Install the trapeze assembly onto the trapeze adapter according to the trapeze manufacturer s instructions 4 Operate the bed from its highest through lowest position...

Page 20: ...FLEX bed is intended for use in an electromagnetic environment for professional healthcare in which radiated RF disturbances are controlled The customer or the user of the Direct Supply Panacea 1000 F...

Page 21: ...61000 4 5 0 5 kV 1 kV line s to line s 0 5 kV 1 kV 2 kV line s to earth 0 5 kV 1 kV line s to line s 0 5 kV 1 kV 2 kV line s to earth Mains power quality should be that of a typical professional heal...

Page 22: ...kHz Portable and mobile RF communications equipment should be used no closer to any part of the Direct Supply Panacea 1000 FLEX bed including cables than the recommended separation distance calculate...

Page 23: ...e to someone else or at the end of the applicable limited warranty period identified below whichever is earlier Warranty Period Parts Only Welds 15 years Mechanical Components 3 years Electronics 3 ye...

Page 24: ...Distributed by Direct Supply Manufacturing Inc 7301 W Champions Way Milwaukee WI 53223 2021 Direct Supply Manufacturing Inc All Rights Reserved Direct Supply Panacea and all associated logos are the...

Reviews: