![Dingsheng Tiangong PY180H Operating Manual Download Page 52](http://html1.mh-extra.com/html/dingsheng-tiangong/py180h/py180h_operating-manual_2505678052.webp)
48
Operating hours
Maintenance
After every 3000
operating hours
Engine: The following work shall be carried out except for
the maintenance items to be conducted after 100h of
operation:
1. Clean the cooling system.
2. Clean the engine oil cooler.
3. Check the internal water seal of water pump and fill new
lubricating grease.
4. Disassemble and check the engine, starter; clean and
maintain fill new lubricating grease.
5. Determine whether to disassemble cylinder cover and
repair
inlet valve according to the relevant conditions.
6. Determine whether to adjust the injection pump
according to the relevant conditions.
7. Determine whether to check the oil supply of engine oil
pump.
8. Replace engine oil filter element.
9. Check the axial clearance at main-drive pinion of rear
axle, if the axial clearance is more than 0.05,
readjustment must be conducted.
8.5 Engine
8.5.1 Engine air filter
a. Air prefilter
According to the using condition, the air prefilter shall be disassembled to
remove dusts with compressed air or water after operating for 100
~
150 hours
,
then
reassemble after the air prefilter becomes dried completely.
b. Air filter
1. When the blocked alarm indicates from green to red, conduct maintenance to
main filter element.
2. The filter element must be replaced after cleaning for 5 times.
3. The main filter element and safety filter element shall be replaced at the same
time when replacing filter.
4. When conducting maintenance to the filter element, beat the filter element
slightly or blow the filter element from inside to outside with compressed air,
reassemble the main filter element after clearing dusts and reset the blocked alarm.
5. It is strictly forbidden to clean filter element with oil or water.
6. When conducting maintenance to the filter element, replace the main filter
element immediately if find damage. Check the air inlet hose from filter to engine for
damage. Take notice of replacing damaged parts.
8.5.2 Fuel system
Note:
When the system is operating, do not contact fuel with open fire and no
Summary of Contents for PY180H
Page 16: ...12 A3 电气接线图 ...
Page 39: ...35 A3 润滑图 ...