![Dinel CLM-36 T Instruction Manual Download Page 18](http://html1.mh-extra.com/html/dinel/clm-36-t/clm-36-t_instruction-manual_2505565018.webp)
CLM–36
©
Dinel, s.r.o.
18
12 . Correct specification examples
CLM–
36
N–10–G–I E1000
(N)
normal (for non-explosive areas);
(10)
uncoated St. steel rod electrode;
(G)
process connection thread G1";
(I)
current (4 ... 20 mA);
(E1000)
length electrode 1000 mm
CLM–36XiT–30–G–I E9750
(XiT)
high-temperature conf. for explosive environments;
(30)
uncoated St. steel rope electrode;
(G)
process connec-
tion thread G1";
(I)
current (4 ... 20 mA)
;
(E9750)
length electrode 9750 mm.
optional – for a surcharge
(see catalogue
sheet of accessories)
• Connector with protection class IP67 (GAN–
DADE 7A) with 5 m cable (current output)
• Connector with protection class IP67 (GAN–
DAAE 7A) with 5 m cable (voltage output)
• Steel welding flange ON–36x2
• St. steel welding flange NN–36x2
• St. steel fixing nut UM–36x2
• Anchor welding cylinder KV–31 (only
CLM–36–31)
• Dust-tight bushing PR–31(only CLM–
36–31)
13 . Accessories
standard
(included in the level meter price)
• 1x of seal, other seals are on request
(PTFE, Al, etc.) *
• 1x connector socket
• 1x screwdriver for adjustment (each 5 pcs)
* Pressure resistance - see the table in the
accessories datasheet in the "seals and
gaskets".