12 Device information
1
Type and order code
WI 120TU
2
Design
Heat source
Water
2.1
Model
Universal
2.2
Controller
integrated
2.3
Thermal energy meter
Integrated
2.4
Installation location
Indoors
2.5
Performance levels
2
3
Operating limits
3.1
Heating water flow
°C
20 to 60 ± 2
3.2
Cold waterRC (heat source)
°C
+7 to +25
4
Flow / sound
4.1
Heating water flow / free compression (max).
Nominal flow in accordance
with EN 14511
at W10...7 / W35...30
m³/h / Pa
20.6 / 36000
at W10...7 / W45...40
m³/h / Pa
19.1 / 40000
at W10...7 / W55...47
m³/h / Pa
11.5 / 64000
Minimum heating water flow
m³/h / Pa
11.5 / 64000
4.2
Cold water flow rate / internal pressure differential
Nominal flow in accordance
with EN 14511
at W10...7 / W35...30
m³/h / Pa
27.7 / 21500
at W10...7 / W45...40
m³/h / Pa
25.1 / 17000
at W10...7 / W55...47
m³/h / Pa
22.4 / 12000
Minimum cold water flow rate
m³/h / Pa
22.4 / 12000
4.3
Sound power level according to EN 12102
dB(A)
66
4.4
Sound pressure level at a distance of 1m
1
dB(A)
53
5
Dimensions, weight and filling quantity
5.1
Device dimensions
2
H x W x L mm
1890 x 1350 x 750
5.2
Weight of the transportable unit(s) incl. packaging
kg
604
5.3
Device connections for heating
inches
Rp 2½“
5.4
Device connections for heat source
Inches
Rp 2½“
5.5
Refrigerant / total filling weight
type/kg
R410A / 23.0
5.6
GWP value / CO
2
equivalent
--- / t
2088 / 48
5.7
Refrigeration circuit hermetically seale
yes
5.8
Lubricant / total filling quantity
type/litres
Polyolester (POE) / 7.3
5.9
Volume of heating water in device
Litres
21
5.10 Volume of heat transfer medium in device
Litres
21
6
Electrical connection
6.1
Supply voltage / fuse protection / RCD-Type
3~/PE 400 V (50 Hz) / C 80A / A
6.2
Control voltage / fuse protection / RCD-Type
1~/N/PE 230 V (50 Hz) / C 13A / A
6.3
Degree of protection according to EN 60 529
IP 21
6.4
Starting current with soft starter
A
53
6.5
Nominal power consumption W10 W35 / max. power consumption
3
kW
20.1 / 35.3
6.6
Nominal current W10 W35 / cos
A / ---
36.3 / 0.8
6.7
Power consumption of compressor protection
(per compressor)
W
90 / thermostatically controlled
6.8
Power consumption of pumps
kW
up to 0.48
7
Complies with the European safety regulations
4
8
Additional model features
8.1
Water in device is protected against freezing
5
Yes
8.2
Max. operating overpressure (heat source/heat sink)
bar
3.0
Summary of Contents for WI 120TU
Page 2: ......
Page 38: ...EN 18 452237 66 53 FD 9912 www gdts one English WI 120TU WI 180TU...
Page 56: ...FR 18 452237 66 53 FD 9912 www gdts one Fran ais WI 120TU WI 180TU...
Page 82: ...A XXVI 452237 66 53 FD 9912 www gdts one Anhang Appendix Annexes WI 120TU WI 180TU...
Page 83: ...www gdts one 452237 66 53 FD 9912 A XXVII WI 120TU WI 180TU Anhang Appendix Annexes...