WI 120TU - WI 180TU
English
Information requirements for heat pump space heaters and heat pump combination heaters
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Tj = - 7°C
P
dh
167,3
kW
Tj = - 7°C
COP
d
3,84
-
Tj = + 2°C
P
dh
172,3
kW
Tj = + 2°C
COP
d
4,40
-
Tj = + 7°C
P
dh
175,4
kW
Tj = + 7°C
COP
d
4,82
-
Tj = + 12°C
P
dh
178,4
kW
Tj = + 12°C
COP
d
5,30
-
Tj = bivalent temperature
P
dh
165,9
kW
Tj = bivalent temperature
COP
d
3,70
-
Tj = operation limit temperature
P
dh
165,9
kW
Tj = operation limit temperature
COP
d
3,70
-
For air-to-water heat pumps
For air-to-water heat pumps:
Tj = -15°C (if TOL < -20°C)
P
dh
165,9
kW
Tj = -15°C (if TOL < -20°C)
COP
d
3,70
-
Bivalent temperature
T
biv
-10
°C
For air-to-water heat pumps:
Operation limit temperature
TOL
-10
°C
Cycling interval capacity for heating
P
cych
-
kW
Cycling interval efficiency
COP
cyc
-
-
Degradation co-efficient (**)
C
dh
0,90
-
Heating water operating limit
temperature
WTOL
62
°C
Power consumption in modes other than active mode
Supplementary heater
Off mode
P
OFF
0,015
kW
Rated heat output (*)
P
sup
0
kW
Thermostat-off mode
P
TO
0,020
kW
Type of energy input
eletrical
Standby mode
P
SB
0,015
kW
Crankcase heater mode
P
CK
0,300
kW
Other items
Capacity control
fixed
-
--
m³ /h
Sound power level, indoors/ outdoors
L
WA
70/--
dB
-
34,7
m³ /h
Emissions of nitrogen oxides
NO
x
-
mg/kWh
Declared load profile
--
Water heating energy efficiency
η
wh
--
%
Daily electricity consumption
Q
elec
--
kWh
Daily fuel consumption
Q
fuel
--
kWh
Contact details
(**) If C
dh
is not determined by measurement nthen the default degradation is C
dh
= 0,9
(--) not applicable
Model
WI 180TU
Air-to-water heat pump
no
Water-to-water heat pump
yes
Brine-to-water heat pump
no
Low-temperature heat pump
no
Equipped with a supplementary heater
no
168
%
Heat pump combination heater
no
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps. For low- temperature heat pumps, parameters
shall be declared for low-temperature application.
Rated heat output (*)
Prated
166
kW
Seasonal space heating energy
efficiency
η
s
Parameters shall be declared for average climate conditions:
For air-to-water heat pumps: Rated
air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Declared capacity for heating foer part load at indoor temperature 20°C and
outdoor temperature T
j
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature T
j
For heat pump combination heater:
Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach
(*) For heat pump space heaters and heat pump combination heaters, the rated output P
rated
is equal to the design load for heating P
designh
, and the rated
heat output of a supplementary capacity for heating sup(
Tj
).
Summary of Contents for WI 120TU
Page 2: ......
Page 38: ...EN 18 452237 66 53 FD 9912 www gdts one English WI 120TU WI 180TU...
Page 56: ...FR 18 452237 66 53 FD 9912 www gdts one Fran ais WI 120TU WI 180TU...
Page 82: ...A XXVI 452237 66 53 FD 9912 www gdts one Anhang Appendix Annexes WI 120TU WI 180TU...
Page 83: ...www gdts one 452237 66 53 FD 9912 A XXVII WI 120TU WI 180TU Anhang Appendix Annexes...