11 Device information
11.1 Device information heat pump
Type and order code
M Flex 0609
M Flex 0916M
M Flex 0916
1
Design
Heat source
Air
Air
Air
1.1
Seasonal coefficient of performance (COP) average climate 35 °C / 55 °C
1.2
Control
Integrated
Integrated
Integrated
1.3
Heat generator installation location
Indoors
Indoors
Indoors
1.4
Heat source installation location
Outside
Outside
Outside
1.5
Thermal energy metering
Integrated
Integrated
Integrated
1.6
Performance levels
Variable
Variable
Variable
2
Operating limits
2.1
Heating water flow / return
1
°C
up to 60 ±2 / from 20
up to 60 ±2 / from 20
up to 60 ±2 / from 20
2.2
Air (heating)
°C
-22 to +35
-22 to +35
-22 to +35
3
Flow
2
/ sound
3.1
Heating water flow / free compression
Nominal flow in accordance with EN 14511
A7/ W35...30
m³/h / Pa
0.8 x 60000
1.2 x 52000
1.2 x 52000
A7 / W45...40
m³/h / Pa
0.8 x 60000
1.2 x 52000
1.2 x 52000
A7 / W55...47
m³/h / Pa
0.6 x 65000
0.8 x 60000
0.8 x 60000
3.2
Minimum heating water flow
m³/h
0.6 x 65000
0.8 x 60000
0.8 x 60000
3.3
Sound power level according to EN 12102 with A7 / W55 outdoors
Normal operation / reduced operation
3
dB(A)
55 x 47
55 x 47
55 x 47
3.4
Sound pressure level at a distance of 10 m, outdoors
4
Normal operation / reduced operation
dB(A)
25 x 24
25 x 24
25 x 24
3.5
Sound power level in accordance with EN 12102
at A7 / W55 indoors
dB(A)
45
45
45
3.6
Sound pressure level at a distance of 1 m indoors
dB(A)
34
34
34
3.7
Air flow
Normal operation / reduced operation
m³/h
3000 x 2600
3800 x 3000
3800 x 3000
4
Dimensions / weight and filling quantity
4.1
Device dimensions
5
internal without connections
H x W x L mm
1400 x 600 x 750
1400 x 600 x 750
1400 x 600 x 750
external without connections
H x W x L mm
1230 x 850 x 600
1230 x 850 x 600
1230 x 850 x 600
4.2
Device connections
heating
inches
G 1 1/4" external thread G 1 1/4" external thread G 1 1/4" external thread
4.3
Weight indoor component without refrigeration circuit module /
refrigeration circuit module / outdoor component
kg
90 / 65 / 90
100 / 75 / 98
100 / 75 / 98
4.4
Refrigerant / total filling weight
type / kg
R410A / 3.8
6
R410A / 4.78
R410A / 4.78
4.5
GWP value / CO
2
equivalent
-- / t
2088 x 7.6
2088 x 9.9
2088 x 9.9
4.6
Lubricant / total filling quantity
type / litres
Polyolester (POE)/1.18 Polyolester (POE)/1.24 Polyolester (POE)/1.24
4.7
Volume of heating water in the indoor component
litres
65
65
65
4.8
Electrical pipe heater
Adjustable levels (factory setting)
kW
2; 4; 6 (6)
2; 4; 6 (6)
2; 4; 6 (6)
4.9
Buffer tank
Nominal volume /max. Operating pressure
litres / bar
50 x 3.0
50 x 3.0
50 x 3.0
4.10 Volume expansion vessel
litres
24
24
24
4.11 Start-to-leak pressure, safety valve
bar
2.5
2.5
2.5