background image

32

DOK4x HOIAO FxDEN · FD 0001

www.glendimplex.de

English

Air-to-water heat pump M Flex

14 Warranty certificate

Glen Dimplex Deutschland

Warranty certificate - System M
(heating heat pumps, central domestic ventilation units)
Valid for Germany and Austria
(issued 02/2020)

The following conditions, describing the requirements and the
scope of our warranty service, do not affect the warranty obliga-
tions of the seller arising from the sales contract with the end cus-
tomer. We offer a warranty for the units subject to the following
conditions:

Based on the following conditions, we remedy defects on the unit
due to material and/or manufacturing defects free of charge, pro-
vided they are reported to us without delay upon being detected
and within 24 months after delivery to the first end customer. This
period is 12 months for spare parts and for commercial use.

This unit is only covered by this warranty if it was purchased by a
customer in one of the member states of the European Union, it is
being operated in Germany or Austria when the defect occurs, and
warranty services can also be rendered in Germany or Austria.

Defects we have recognised as being covered by the warranty are
remedied by free repair of the defective parts at our discretion or re-
placement with fault-free parts. We do not cover exceptional costs
of remedying defects due to the type or location of the unit's use or
poor accessibility of the unit. The customer must ensure free ac-
cess to the unit. Dismantled parts which we take back become our
property. The warranty period for rework and spare parts ends with
the expiration of the original warranty period for the unit. The war-
ranty does not cover easily breakable parts which have only an in-
significant effect on the value or usability of the unit. The original
purchase receipt, with purchase or delivery date, must always be
presented.

The warranty becomes void if the customer or a third party has
failed to comply with the applicable VDE regulations, the regula-
tions issued by local utility companies or our installation and oper-
ating instructions, or the information on maintenance work and the
installation diagrams included in the project planning documents,
or if the accessories required for proper functioning have not been
used. We accept no liability for the consequences of modifications
and work activities performed improperly by the end customer or a
third party. The warranty covers the unit and the parts purchased
from the supplier. Parts and units not purchased from the supplier,
and unit/system defects due to parts not purchased from the sup-
plier are not covered by the warranty.

If it was not possible to remedy the defect, the manufacturer shall
either deliver a replacement free of charge or issue a reimburse-
ment for the reduced value. In cases in which replacement is pro-
vided, we reserve the right to apply a reasonable utilisation charge
for the period of usage elapsed to date. Additional or further claims,
in particular regarding compensation for damage caused outside of
the unit, are excluded.

It is possible to extend the warranty under certain conditions by tak-
ing out a Care Basic warranty package (extension from 2 to 5 years).

For further details, visit: 

https://gdts.one/building-climate-solutions/waermepumpen/sys-
tem-m/service

The prerequisite for accepting the extended warranty is chargeable
commissioning by the authorised after-sales service for complete
systems (see fixed charges in the service price list) with an opera-
tional suitability assessment within an operating time (compressor
runtime) of less than 150 hours. The chargeable assessment of op-
erational suitability by the after sales service for complete systems
is ordered in writing using the corresponding order form or using
the online order facility on the Internet (www.dimplex.de/garantiev-
erlaengerung). Complete payment of the fixed charge is a prerequi-
site for confirmation of the warranty time extension. If any defects
are noted in the operational suitability assessment log, they must
be remedied. The warranty time extension is confirmed from the
address specified below after successful assessment of operational
suitability and submission of the log by the after sales service for
complete systems to GDTS. The prerequisite is a review of the data
in the operational suitability assessment log and approval by GDTS.
The warranty ends at the latest 72 months from delivery from the
factor or 78 months from the date of manufacture.

The fixed charge includes the work performed to assess operational
suitability plus travel costs. No liability is assumed for proper plan-
ning, dimensioning and execution of the overall system. Remedying
system defects and waiting times are extra services.

The current fixed rates and the associated services can be found on
the Internet at: http://www.dimplex.de/garantieverlaengerung.
There is also an online order form here.

Glen Dimplex Deutschland

Glen Dimplex Deutschland GmbH
Department: Service
Am Goldenen Feld 18
95326 Kulmbach

For order processing, the 

type

, the 

serial number S/N

, the date of

manufacture 

FD

 and, if specified, the customer service index 

KI

 for

the unit are required.
This information is listed on the unit’s type plate.

After-sales service address:

Tel:
Fax no.:
E-mail address:
Internet:

+49 (0)9221 709 545
+49 (0)9221 709 924545
[email protected]
www.glendimplex.de
www.dimplex.de/garantieverlaengerung
www.dimplex.de/seviceauftrag

Summary of Contents for M Flex Air

Page 1: ...K4x HOIAO FxDEN EN FD 0001 M Flex 0609 M Flex 0916 M Flex 0916M Installation and Operating Instruction Air to water heat pump in integral design Glen Dimplex Deutschland Dimplex 09CHOIAOF6 16IHOIAOF6...

Page 2: ......

Page 3: ...tric wire 11 6 2 Condensate drain 11 6 3 Connection on heating side 11 6 4 Domestic hot water connection 12 6 5 Temperature sensor connection 13 6 6 Electrical connection 14 6 7 Hydraulic integration...

Page 4: ...2 DOK4x HOIAO FxDEN FD 0001 www glendimplex de English Air to water heat pump M Flex 15 Information on the use of data 33 16 Declaration of conformity 34...

Page 5: ...fur ther connection requirements stipulated by local utility compa nies must also be observed When connecting the heating system all country specific reg ulations must also be adhered to This unit ca...

Page 6: ...ls the air i e ex tracts heat from it This extracted heat is then transferred to the working medium refrigerant in the evaporator The heat is pumped to a higher temperature level by increas ing its pr...

Page 7: ...ulating pump 5 Switch box with heating controller 6 Electric additional heater 2 4 or 6 kW for higher domestic hot water temperatures and for heating support 7 Safety valve start to leak pressure 2 5...

Page 8: ...6 DOK4x HOIAO FxDEN FD 0001 www glendimplex de English Air to water heat pump M Flex 3 2 Outdoor unit 1 Evaporator 2 Fan 3 Expansion valve 4 Switch box 5 Connection for refrigerant line 1 2 4 3 5 5...

Page 9: ...ed directly underneath the pallet To lift from the pallet the indoor unit can be tilted back by up to 45 and lifted by the handles on the back at the top Tilting more than 45 is not permitted Once the...

Page 10: ...nglish Air to water heat pump M Flex After the final positioning at the installation location remove the transport fastening on the sprung floor of the compressor on both sides ATTENTION Before commis...

Page 11: ...tion site Cap 12 1 on page 26 The responsibility for the heat pump installation lies with the specialist system construction company During the installation local requirements such as building regula...

Page 12: ...refrigeration lines have been connected to the indoor unit The domestic hot water sensor pre installed on the indoor unit must be inserted in the designated immersion sleeve of the cyl inder Neither...

Page 13: ...ons of the countries in question must be observed 6 3 Connection on heating side Before connecting the heating system to the heat pump the heating system must be flushed to remove any impurities resi...

Page 14: ...ed with a suitable frost protection if heat pump systems are implemented in buildings where a power failure can not be detected holiday home 6 4 Domestic hot water connection Installation and commissi...

Page 15: ...ay that all weather conditions are taken into consideration and the meas ured value is not falsified Mount on the external wall on the north or north west side where possible Do not install in a shelt...

Page 16: ...N FD 0001 www glendimplex de English Air to water heat pump M Flex 6 6 Electrical connection 6 6 1 Electrical diagram integration example Symbol legend see cap 6 6 2 on page 15 Equipment marking see c...

Page 17: ...A451 Cooling active B3 Domestic hot water thermostat B4 Swimming pool water thermostat E10 1 Electric heater E10 2 3 Oil gas boiler H5 Remote fault indicator K21 Flange heater K22 Utility block K23 Di...

Page 18: ...t be connected on plug X1 1 230V IN white on the adapter board The supply cable L N PE 230 V 50 Hz must have a continuous voltage For this reason it should be tapped upstream from the util ity company...

Page 19: ...www glendimplex de DOK4x HOIAO FxDEN FD 0001 17 Air to water heat pump M Flex English 6 7 Hydraulic integration diagram 6 7 1 Hydraulic integration diagram integration example...

Page 20: ...p M Flex 6 7 2 Symbol legend Isolating valve Safety valve combination Circulating pump Room temperature controlled valve Isolating valve with check valve Heat consumer temperature sensor Check valve T...

Page 21: ...lines must be estab lished using the brazing process All generally applicable instal lation and work steps must be followed for this The reducing sleeves provided must be used for connecting the outdo...

Page 22: ...hed An absolute pressure of at least 0 2 mbar must be achieved during evacuation Pressures below 0 2 mbar are advisable however Close the vacuum pump and start filling immediately Step 4 Filling Once...

Page 23: ...Ensure that the condensate drain functions properly The outflow from the heating water pressure relief valve must also function correctly The system must be completely filled with refrigerant and the...

Page 24: ...ned by a heating technician Based on current information we recommend using a 5 phosphoric acid solution for cleaning purposes However if cleaning needs to be performed more frequently a 5 formic acid...

Page 25: ...from the power supply HINWEIS NOTE Personal protective equipment protective goggles safety shoes and gloves where necessary must be used when work ing on the device Components with plastic parts must...

Page 26: ...e of 10 m outdoors4 Normal operation reduced operation 3 dB A 25 x 24 25 x 24 25 x 24 3 5 Sound power level in accordance with EN 12102 at A7 W55 indoors dB A 45 45 45 3 6 Sound pressure level at a di...

Page 27: ...ystem according to EN 14511 For an analysis of the economic and energy efficiency of the system other parameters in particular the defrosting capacity the bivalence point and regulation should also be...

Page 28: ...m 0 5 m 0 5 m 460 39 710 40 790 850 1231 600 206 790 538 695 995 95 174 120 55 105 40 538 39 2 3 27 110 40 205 108 160 30 30 50 710 778 372 1 1 1 7 1 2 1 3 1 4 1 8 1 5 1 6 1 1 1 2 1 3 Air intake Direc...

Page 29: ...AO FxDEN FD 0001 27 Air to water heat pump M Flex English 12 2 Dimension drawing indoor unit 2 8 2 9 2 1 2 10 2 3 2 2 2 7 2 12 2 11 600 1400 544 722 750 113 125 95 0 117 187 490 560 840 910 980 1050 1...

Page 30: ...ugh refrigerant line 18 mm 1 6 Optional feedthrough electric wires 12 mm 1 7 Optional feedthrough electric wire 1 8 External dimensions wood design variant 2 Indoor unit 2 1 Outlet overpressure 2 2 Fe...

Page 31: ...55 dB m h Emissions of nitrogen oxides NOx mg kWh Declared load profile Water heating energy efficiency wh Daily electricity consumption Qelec kWh Daily fuel consumption Qfuel kWh Contact details If C...

Page 32: ...mg kWh Declared load profile Water heating energy efficiency wh Daily electricity consumption Qelec kWh Daily fuel consumption Qfuel kWh Contact details If Cdh is not determined by measurement nthen...

Page 33: ...mg kWh Declared load profile Water heating energy efficiency wh Daily electricity consumption Qelec kWh Daily fuel consumption Qfuel kWh Contact details If Cdh is not determined by measurement nthen...

Page 34: ...ered by the warranty If it was not possible to remedy the defect the manufacturer shall either deliver a replacement free of charge or issue a reimburse ment for the reduced value In cases in which re...

Page 35: ...t en cryption methods III Use of service providers Personal data required for maintenance purposes such as your address contact details and framework data on the contract is made available to after sa...

Page 36: ...DOK4x HOIAO FxDEN FD 0001 www glendimplex de English Air to water heat pump M Flex 16 Declaration of conformity You can find and download the current CE conformity declaration at https glendimplex de...

Page 37: ...www glendimplex de DOK4x HOIAO FxDEN FD 0001 35 Air to water heat pump M Flex English...

Page 38: ...36 DOK4x HOIAO FxDEN FD 0001 www glendimplex de English Air to water heat pump M Flex...

Page 39: ...www glendimplex de DOK4x HOIAO FxDEN FD 0001 37 Air to water heat pump M Flex English...

Page 40: ...glendimplex de www glendimplex de Gesch ftsstelle sterreich Glen Dimplex Austria GmbH Hauptstra e 71 A 5302 Henndorf am Wallersee T 43 6214 20330 F 43 6214 203304 info dimplex at www dimplex at Offic...

Reviews: