EN-18 452162.66.14 · FD 9607
www.dimplex.de
English
LAK 6IMR-TP - LAK 14ITR-TP
12 Device information
1
Type and order code
LAK 6IMR-TP
LAK 9IMR-TP
LAK 14ITR-TP
2
Design
Heat source
Air
Air
Air
2.1
Model
Split reversible
Split reversible
Split reversible
2.2
Controller
WPM Econ
WPM Econ
WPM Econ
2.3
Thermal energy metering
no
no
no
2.4
Installation location
Indoors / outdoors
Indoors / outdoors
Indoors / outdoors
2.5
Performance level
Variable
Variable
Variable
3
Operating limits
3.1
Heating water flow / return
°C
up to 55 / from 20
up to 55 / from 20
up to 55 / from 20
3.2
Cooling water flow
°C
7 to 25
7 to 25
7 to 25
3.3
Air (heating)
°C
-20 to +30
-20 to +30
-20 to +30
3.4
Air (cooling)
°C
+10 to +43
+10 to +43
+10 to +43
4
Flow / sound
4.1
Heating water flow / internal pressure differential
in accordance with EN 14511
m³/h / Pa
1.6 / 20000
1.6 / 20000
2.4 / 30400
free compression
Pa
38800
38800
29600
Minimum heating water flow
m³/h / Pa
0.75 / 8500
0.75 / 8500
0.9 / 10000
free compression
Pa
68500
68500
77300
4.2
Noise-power level in accordance with EN 12102 outdoors
1
dB(A)
63
63
67
4.3
Sound pressure level in 10 m distance, outdoors
2
dB(A)
32
32
36
4.4
Noise-power level in accordance with EN 12102 indoors
dB(A)
42
42
42
4.5
Sound pressure level at a distance of 1 m indoors
dB(A)
35
35
35
4.6
Air flow
m³/h
3600
3600
3600
5
Dimensions, weight and filling quantities
5.1
Device dimensions
3
indoors
H x W x D mm
outdoors
H x W x D mm
694 x 450 x 240
834 x 950 x 330
694 x 450 x 240
834 x 950 x 330
694 x 450 x 240
1380 x 950 x 330
5.2
Weight of the transport unit(s)
incl. packaging indoors / outdoors
kg
23 / 69
23 / 69
25 / 116
5.3
Device connections for heating
inches
G 1A
G 1A
G 1A
5.4
Refrigerant; total filling weight
type/kg
R410A / 1.9
R410A / 1.9
R410A / 2.98
5.5
Lubricant; total filling quantity
type/litres
Polyvinyl ether (PVE) /
0.9
Polyvinyl ether (PVE) /
0.9
Polyvinyl ether (PVE) /
1.3
5.6
Volume of heating water in the outdoor component
Litres
0
0
0
5.7
Electrical pipe heater
kW
2.4 or 6
4
2.4 or 6
2.4 or 6
5.8
Start-to-leak pressure, safety valve
bar
2.5
2.5
2.5
6
Electrical connection
6.1
Supply voltage / fuse protectionCompressor
1~/N/PE 230 V (50 Hz)
/ C25 A
1~/N/PE 230 V (50 Hz)
/ C25 A
Electrical pipe heater
1~/N/PE 230 V (50 Hz)
/ C32 A
1~/N/PE 230 V (50 Hz)
/ C32 A
Comp electrical pipe heater
3~/N/PE 400 V (50 Hz)
/ C25 A
3~/N/PE 400 V (50 Hz)
/ C25 A
3~/N/PE 400 V (50 Hz)
/ C25 A
RCD type
B
B
B
6.2
Control voltage / fuse protection
1~/N/PE 230 V (50 Hz)
/ C13 A
1~/N/PE 230 V (50 Hz)
/ C13 A
1~/N/PE 230 V (50 Hz)
/ C13 A
6.3
Degree of protection according to EN 60 529 indoors/outdoors
IP 20 / IP X4
IP 20 / IP X4
IP 20 / IP X4
6.4
Starting current limiter
Inverter
Inverter
Inverter
6.5
Rotary field monitoring
Yes
Yes
Yes
6.6
Starting current
A
1.2
1.2
1.3
6.7
Nominal power consumption at A7/W35 / max. consumption
5
6
kW
1.17 / 8.39
7
2.11 / 9.41
6.8
Nominal current at A7/W35 / cos
A / --
5.14 / 0.99
9.27 / 0.99
4.94 / 0.99
6.9
Nominal power consumption A2 / W35
1.41
1.91
3.50
6.10 Power consumption of compressor protection (per compressor) W
--
--
--
6.11 Power consumption of fan
W
124
124
248
7
Complies with the European safety regulations
8
Summary of Contents for LAK 14ITR-TP
Page 2: ......
Page 22: ...TR 20 452162 66 14 FD 9607 www dimplex de Türkçe LAK 6IMR TP LAK 14ITR TP ...
Page 42: ...EN 20 452162 66 14 FD 9607 www dimplex de English LAK 6IMR TP LAK 14ITR TP ...
Page 62: ...PL 20 452162 66 14 FD 9607 www dimplex de Polski LAK 6IMR TP LAK 14ITR TP ...
Page 79: ...www dimplex de 452162 66 14 FD 9607 A XVII Ek Appendix Załącznik LAK 6IMR TP LAK 14ITR TP ...