www.glendimplex.de
DOK4SVxxDEN · FD 9912
11
Domestic ventilation unit M Flex Air (Plus)
English
6 Installation
The ventilation system must be installed carefully by a qualified
engineer in compliance with the installation instructions, the
safety rules for electrical equipment, applicable standards and
relevant local regulations, as well as the rules and regulations
for accident prevention.
Improper or incorrect installation can cause significant hazards,
e.g. serious accidents or fires. Settings and programming not
described in the installation instructions may be relevant to
safety and must be performed only by an engineer.
6.1 Requirements for the
installation location
The installation location for the ventilation unit must be dry and
free from frost. The ambient temperature in the installation
room must not fall below +10 °C and must not rise above +
40 °C. The installation room must not suffer from odours. Suit-
able installation locations include ancillary rooms, e.g. utility
rooms and building services rooms, cellars, storage rooms and
attics. Effective and frost-free drainage of condensate water
must be guaranteed.
There must be sufficient space for maintenance and repair
work.
Fig. 6.1: Vertical installation
Fig. 6.2:Horizontal installation (top view)
!!
CAUTION!
The required minimum clearances must be observed for in-
stallation.
!!
CAUTION!
The ventilation unit and the corresponding power supply dis-
connect device must be freely accessible.
HINWEIS
ºº
º
ºº
º
NOTE
The air circuit made up of all air inlets and outlets, as well as
overflow passages, must not be obstructed, covered or
sealed. Settings carried out by the engineer must not be
changed.
!!
CAUTION!
Changes to the unit or on the installed complete system, as
well as any structural changes, can have an impact on safety
and must therefore be agreed with an engineer.
!!
CAUTION!
Special requirements apply for simultaneous use of ventila-
tion systems and fireplaces. Country-specific and regional
rules and regulations must be observed. Early consultation
with the relevant chimney sweep is strongly recommended!
HINWEIS
ºº
º
ºº
º
NOTE
The unit must not be installed at altitudes greater than 2,000
m above sea level.
It must be possible to shut off combustion air lines and exhaust
gas systems for fireplaces that depend on room air to ensure
fault-free operation of the ventilation unit.
0,6 m
0,6 m
0,6 m
0,6 m