WARNING Please Read Carefully

Note to Installers

This 

Warning

 contains vital information. As the only individual in

contact with system users, it is the installer’s responsibility to

bring each item in this Warning to the attention of all users of this

system.

System Failures

This system has been carefully designed to be as effective as

possible. There are circumstances, however, involving fire, bur-

glary, or other types of emergencies where it may not provide

protection. Any alarm system of any type may be compromised

deliberately or may fail to operate as expected for a variety of

reasons. Some but not all of these reasons may be:

Access by Intruders

Intruders may enter through an unprotected access point, cir-

cumvent a sensing device, evade detection by moving through

an area of insufficient coverage, disconnect a warning device, or

interfere with or prevent the proper operation of the system.

Component Failure

Although every effort has been made to make this system as

reliable as possible, the system may fail to function as intended

due to the failure of a component.

Compromise of Radio Frequency (Wireless) Devices

Signals may not reach the receiver under all circumstances

which could include metal objects placed on or near the radio

path or deliberate jamming or other inadvertent radio signal

interference.

Criminal Knowledge

This system contains security features which were known to be

effective at the time of manufacture. It is possible for persons

with criminal intent to develop techniques which reduce the

effectiveness of these features. It is important that your security

system be reviewed periodically to ensure that its features

remain effective and that it is updated or replaced if it is found

that it does not provide the protection expected.

Failure of Replaceable Batteries

This system’s wireless transmitters have been designed to pro-

vide several years of battery life under normal conditions. The

expected battery life is a function of the device environment,

usage, and type. Ambient conditions such as high humidity, high

or low temperatures, or large temperature fluctuations may

reduce the expected battery life. While each transmitting device

has a low battery monitor which identifies when the batteries

need to be replaced, this monitor may fail to operate as

expected. Regular testing and maintenance will keep the sys-

tem in good operating condition.

Inadequate Installation

A security system must be installed properly in order to provide

adequate protection. Every installation should be evaluated by a

security professional to ensure that all access points and areas

are covered. Locks and latches on windows and doors must be

secure and operate as intended. Windows, doors, walls, ceil-

ings and other building materials must be of sufficient strength

and construction to provide the level of protection expected. A

reevaluation must be done during and after any construction

activity. An evaluation by the fire and/or police department is

highly recommended if this service is available.

Inadequate Testing

Most problems that would prevent an alarm system from oper-

ating as intended can be found by regular testing and mainte-

nance. The complete system should be tested weekly and

immediately after a break-in, an attempted break-in, a fire, a

storm, an earthquake, an accident, or any kind of construction

activity inside or outside the premises. The testing should

include all sensing devices, keypads, consoles, alarm indicating

devices, and any other operational devices that are part of the

system.

Insufficient Time

There may be circumstances when the system will operate as

intended, yet the occupants will not be protected from an emer-

gency due to their inability to respond to the warnings in a timely

manner. If the system is remotely monitored, the response may

not occur in time to protect the occupants or their belongings.

Motion Detectors

Motion detectors can only detect motion within the designated

areas as shown in their respective installation instructions. They

cannot discriminate between intruders and intended occupants.

Motion detectors do not provide volumetric area protection.

They have multiple beams of detection and motion can only be

detected in unobstructed areas covered by these beams. They

cannot detect motion which occurs behind walls, ceilings, floor,

closed doors, glass partitions, glass doors or windows. Any type

of tampering whether intentional or unintentional such as mask-

ing, painting, or spraying of any material on the lenses, mirrors,

windows or any other part of the detection system will impair its

proper operation.

Passive infrared motion detectors operate by sensing changes

in temperature. However their effectiveness can be reduced

when the ambient temperature rises near or above body tem-

perature or if there are intentional or unintentional sources of

heat in or near the detection area. Some of these heat sources

could be heaters, radiators, stoves, barbeques, fireplaces, sun-

light, steam vents, lighting and so on.

Power Failure

Control units, intrusion detectors, smoke detectors and many

other security devices require an adequate power supply for

proper operation. If a device operates from batteries, it is possi-

ble for the batteries to fail. Even if the batteries have not failed,

they must be charged, in good condition and installed correctly.

If a device operates only by AC power, any interruption, how-

ever brief, will render that device inoperative while it does not

have power. Power interruptions of any length are often accom-

panied by voltage fluctuations which may damage electronic

equipment such as a security system. After a power interruption

has occurred, immediately conduct a complete system test to

ensure that the system operates as intended.

Security and Insurance

Regardless of its capabilities, an alarm system is not a substi-

tute for property or life insurance. An alarm system also is not a

substitute for property owners, renters, or other occupants to act

prudently to prevent or minimize the harmful effects of an emer-

gency situation.

Smoke Detectors

Smoke detectors that are a part of this system may not properly

alert occupants of a fire for a number of reasons, some of which

follow. The smoke detectors may have been improperly

installed or positioned. Smoke may not be able to reach the

smoke detectors, such as when the fire is in a chimney, walls or

roofs, or on the other side of closed doors. Smoke detectors

may not detect smoke from fires on another level of the resi-

dence or building.

Every fire is different in the amount of smoke produced and the

rate of burning. Smoke detectors cannot sense all types of fires

equally well. Smoke detectors may not provide timely warning

of fires caused by carelessness or safety hazards such as

smoking in bed, violent explosions, escaping gas, improper

storage of flammable materials, overloaded electrical circuits,

children playing with matches or arson.

Even if the smoke detector operates as intended, there may be

circumstances when there is insufficient warning to allow all

occupants to escape in time to avoid injury or death.

Telephone Lines

If telephone lines are used to transmit alarms, they may be out

of service or busy for certain periods of time. Also an intruder

may cut the telephone line or defeat its operation by more

sophisticated means which may be difficult to detect.

Warning Devices 

Warning devices such as sirens, bells, horns, or strobes may

not warn people or waken someone sleeping if there is an inter-

vening wall or door. If warning devices are located on a different

level of the residence or premise, then it is less likely that the

occupants will be alerted or awakened. Audible warning devices

may be interfered with by other noise sources such as stereos,

radios, televisions, air conditioners or other appliances, or pass-

ing traffic. Audible warning devices, however loud, may not be

heard by a hearing-impaired person.

Summary of Contents for GS2060

Page 1: ...ractive to SMS Command and Control Als Removed reference to SMS Notification These are minor changes Notes Description TL260GS TL265GS GS2060 GS2065 V1 1 INSTALLATION MANUAL NA UL ULC ENG FRE EU SPA Type 33 01 8 5 x 11 White Paper Pieces 13 Printing Instructions Master Size 5 5 x 8 5 Number of Sheets in Master 52 2 Sided Printing Cover Printing Not Required Finishing Signature Booklet Note Booklet...

Page 2: ...ormation on the limitations as to liability of the manufacturer Attention Ce manuel contient des informations sur les restrictions concernant le fonctionnement et l utilisation du produit et des informations sur les restrictions en ce qui concerne la responsabilité du fabricant La totalité du manuel doit être lu attentivement Advertencia Por favor consulte el Manual de Instrucciones del Sistema pa...

Page 3: ...Agreement 12 Limited Warranty 13 Français 14 Español 29 NOTE This document does not include the GPRS Ethernet Module Programming Sections Panel Section 851 Refer to DSC Programming Worksheets document Part Number 29007620R004 included with the Communi cator The installation instructions in this document apply to GS2060 GS2065 and TL260GS TL265GS Commu nicators only IMPORTANT The GPRS Ethernet Comm...

Page 4: ...s or their belongings Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beam...

Page 5: ... in UL ULC Listed systems Notes for using Private Corporate and High Speed Data Networks Network access and domain access policies shall be set to restrict unauthorized network access and spoofing or Denial of Service DoS attacks Select an Internet Service Provider ISP that has redundant servers sys tems back up power routers with firewalls enabled and methods to identify and protect against DoS a...

Page 6: ...CT or a Public Switched Data Network PSDN transmitter where the PSDN provides the line security and is the primary line In this mode alarm signals are required to be sent simultaneously over both communication methods Ratings Compatibility Products or components of products which perform communications functions only shall comply with the requirements applicable to communications equipment as spec...

Page 7: ... connections 3 On the SIM card holder push gently to slide the cover towards the Printed Circuit Board PCB antenna as indicated by the arrow on SIM holder to OPEN This will unlatch the SIM card holder on the side closest to edge of the Communicator PCB 4 Lift up the SIM card holder from the side that is not hinged 5 Insert or remove the SIM card noting the orientation of the notches on the SIM car...

Page 8: ... antenna connector firmly into the socket on the GSM radio See Figure 3 g Place the nylon washer with bushing thick flat washer onto the threaded section of the antenna cable Insert the threaded section through the antenna mounting knockout hole Place the second nylon washer flat followed by the brass washer and the brass nut onto the threaded section of the cable outside the panel Tighten the ass...

Page 9: ...he Communicator has been powered up the module will request pro gramming from Connect24 c At the keypad enter 8 Installer Code 382 and confirm that Toggle Option 5 is ON GPRS Ethernet Module Enabled NOTE Initialization may take several minutes to complete Red and yellow LEDs will flash together during initialization Do not leave the installation until the red and yellow LEDs have stopped flash ing...

Page 10: ...log will occur for the following trouble conditions Receiver Not Available Trouble Receiver Supervision Trouble or Failure to Communicate FTC Trouble T Link Comm Fault Restore This log will occur when the panel loses communications with the Communi cator and will clear when communications is restored Installing the GS2065 TL265GS with the ALEXOR PC9155 Panel NOTE With GS2065 Communicator Panel is ...

Page 11: ...hed Telephone Network PSTN Entering a 4 digit hexadecimal value for a telephone number will change the call routing as determined by the number programmed DCAAF Internal All Receivers Signals will be routed depending on Section 851 006 programming DCBBF Ethernet Receiver 1 Primary TL260GS TL265GS only DCCCF Ethernet Receiver 2 Backup TL260GS TL265GS only DCDDF GPRS Receiver 1 Primary DCEEF GPRS Re...

Page 12: ...move and discard the circular knockout at the top right of the panel c Insert a small flathead screwdriver between the antenna cable and the radio See Figure 4 Gently pry the plug loose from the radio and remove the other end of the antenna cable from the PCB NOTE Removing the antenna cable using only your fingers may cause damage to the connector d Using instructions supplied with the kit install...

Page 13: ... SIM lock feature has been enabled and the unit has not been programmed with the correct PIN for the SIM card GSM Trouble 5 Flashes This trouble is indicated for any of the following 4 conditions a Radio Failure Trouble is indicated after 8 failed attempts to communicate with the GSM radio b SIM Failure Trouble is indicated after 10 failed CPIN commands c GSM Network Trouble Trouble is indicated f...

Page 14: ...tings by installing the hardware jumper Perform the following steps to reset the Communicator NOTE Two pins require a jumper in order to reset the hardware values 1 Remove panel front cover 2 Locate the AUDIO DEFAULT 5 pin connector in the middle of the Communicator board On the PC1616 1832 1864 pan els pins 4 and 5 are on top See Figure 3 On the PC9155 panel pins 4 and 5 are on the right See Figu...

Page 15: ...etwork administrator Yellow LED 7 Flashes Receiver Not Available Ensure that the Ethernet path has internet connectivity Confirm that SIM does not have a custom APN The unit will not allow connection to the internet with custom APNs If you are using a static IP address make sure the gateway and subnet mask are entered correctly If the network has a firewall ensure the network has the programmed ou...

Page 16: ...EULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA In such event You must destroy all copies of the SOFTWARE PRODUCT and all of i...

Page 17: ... manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under war ranty will be credited or replaced at DSC s option Prod ucts not covered by this warranty or otherwise out of warranty due to age misuse or damage shall be evalu ated and a repair estimate shall be provided No repair work will be ...

Page 18: ......

Page 19: ...e licence d utilisation 29 GARANTIE LIMITÉE 30 NOTE Ce document n inclut pas la programmation du module GPRS Ethernet Section de panneau 851 Consultez le document Fiches de programmation DSC Référence 29007620R001 inclus avec le Communicator Les instructions d installation de ce document ne concernent que les Communicator GS2060 GS2065 et TL260GS TL265GS IMPORTANT Le Communicator GPRS Ethernet est...

Page 20: ...ur un certains nombre de raisons en voici quelques une Le détecteurs de fumée peuvent avoir été mal installés ou positionnés La fumée peut ne pas pouvoir atteindre le détecteurs de fumée par exemple un incendie dans une cheminée murs ou toits ou de l autre côté de portes fermées Les détecteurs de fumée peuvent ne pas détecter la fumée provenant d incendies à un autre niveau de la résidence ou du b...

Page 21: ...rne homologuée UL ULC adaptée à l application source extérieure limitée en puissance L alimentation doit être de classe II de puissance limitée Exigences d installation UL ULC NOTE Pour les équipements utilisés dans les locaux protégés et destinés à faciliter les communications IP concentrateurs routeurs NID modems câble DSL une sauvegarde d alimentation 24 heures est obligatoire Quand ce n est pa...

Page 22: ... option 005 Toggle Option 1 Ethernet et ou Toggle Option 2 GSM doit être ON Toggle Option 3 Type de supervision doit être ON et l intervalle de battement de cœur de supervision doit être réglé à 0087 135 secondes Option 004 0087 La fenêtre de supervision sur la station de supervision doit être au maximum 00C8 200 secondes Pour les systèmes de sécurité en ligne chiffrés le chiffrement AES128 doit ê...

Page 23: ... disposant d une connectivité Ethernet Internet jusqu au module Communicator dans l armoire du panneau de contrôle Le côt Communicator du câble doit être équipé d une fiche RJ45 à connecter à la prise RJ45 du Communicator Toutes les exigences d installation d un câble Ethernet CAT5 doivent être respectées pour un bon fonctionnement du Communicator notamment mais sans limitation Ne PAS dénuder la g...

Page 24: ...mmunicator dans le panneau de contrôle le Communicator téléchargera automatiquement sa programmation auprès de Connect24 dès qu il sera connecté et initialisé NOTE Après l installation initiale vous pourrez ouvrir une session sur le site web Connect24 à tout moment pour reconfigurer à distance le Communicator à l aide du compte créé pour cette installation Pous plus d informations consultez le sit...

Page 25: ... Reliez un fil de la borne GND du Communicator à la borne AUX du panneau d Reliez un fil de la borne SHLD du Communicator à la borne EGND du panneau Terre de protection e En cas d utilisation d une sonnerie sirène reliez un fil de la borne PWR droite du Communicator à la borne positive de la sonnerie sirène Voir Figure 2 f En cas d utilisation d une sonnerie sirène reliez la borne BELL du panneau ...

Page 26: ...trale par le réseau RTC réseau téléphonique commuté b DCAA Récepteur 0 les signaux seront routés vers les récepteurs GPRS Ethernet 1 4 selon la pro grammation de la Section 006 c La section 301 définit le réseau de communication principal et peut être configurée comme routage RTC ou Communicator La Section de panneau 302 est redondante et la Section 303 est le numéro de téléphone de secours pour l...

Page 27: ...ction pour la programmation du panneau Notez les valeurs modifiées par rapport à leurs valeurs par défaut dans les Fiches de programmation appropriées pour le panneau et du Communicator NOTE Pour la programmation des Toggle Options la bascule est ON quand le numéro est affiché et OFF s il n est pas affiché par exemple 1 5 les options de bascule 1 et 5 sont ON toutes les autres sont OFF 8 Section d...

Page 28: ...ils surviennent sur un Communicator sur le panneau PC9155 Consultez le manuel d installation PC9155 pour plus d informations 1 Pour confirmer que l emplacement du panneau et de l antenne conviennent pour l utilisation de la radio effectuez ce test d emplacement du Communicator NOTE Vous devrez peut être déplacer le panneau ou installer une extension d antenne en option si la force du signal radio ...

Page 29: ...témoin LED 1 vert est clignotant il faut envisager un repositionnement a Montez le support d extension d antenne à l emplacement qui a donné la meilleure force de signal 4 Vous pouvez aussi repositionner le panneau de contrôle pour améliorer la force du signal Démontez le panneau et déplacez le ailleurs pour obtenir la force de signal voulue Si le panneau est déplacé pour améliorer la force du sig...

Page 30: ...ion défaut de connexion à APN défaut d ouver ture d un socket nombre totale d erreurs en commande cyclique 20 ou réception d un MSDI 1 2 7 8 14 Le défaut s efface après réussite des commandes d initialisation et cyclique et réussite des comman des MIPCALL et MIPOPEN d Force du signal insuffisante Le défaut apparaît quand la force moyenne calculée du signal est trop fai ble Les deux témoins LED ver...

Page 31: ...yen est inférieur à 6 La force du signal du Communicator est visible dans Connect24 Témoins LED d activité réseau rouge et vert Activité Ethernet Le témoin LED rouge clignote rapidement une fois pour une émission Ethernet ou deux fois pour une réception Ethernet Activité GPRS Le témoin LED vert 2 clignote rapidement une fois pour une émission GPRS ou deux fois pour une réception GPRS Activité SMS ...

Page 32: ...aut matérielles en position avant de commencer une mise à jour du logiciel interne Le logiciel interne de l appareil peut être mis à jour par GPRS ou par Ethernet Mise à jour à distance ou locale Au début de la mise à jour du logiciel interne tous les témoins LED sont allumés Pendant la procédure de mise à jour du logiciel interne les témoins LED s allument cycliquement en guirlande Après une mise...

Page 33: ...administrateur réseau Témoin LED jaune 7 éclairs Récepteur non disponible Vérifiez que le réseau Ethernet dispose d une connexion à l Internet Vérifiez que la carte SIM n a pas un APN personnalisé Le groupe n autorise pas la connexion à l Internet avec des APN personnalisés Si vous utilisez une adresse IP statique vérifiez que l adresse de passerelle et le masque de sous réseau sont entrés correct...

Page 34: ...tes les mises à niveau et ce CLU et à condition que le récipiendaire accepte les conditions de ce CLU Si le PRODUIT LOGICIEL est une mise à niveau tout transfert doit également inclure toutes les versions antérieures du PRODUIT LOGICIEL f Résiliation Sous réserve de tous ses autres droits DSC se réserve le droit de résilier ce CLU si Vous ne respectez pas les modalités de ce CLU Dans ce cas Vous d...

Page 35: ...y a un problème de réparation du produit après un nombre raisonnable de tentatives au titre de la présente garantie les obligations contractuelles de la société Digi tal Security Controls seront limitées au remplacement du produit comme seule réparation de l inobservation de la garantie En aucun cas la Société Digital Security Controls ne sera responsable des dommages particu liers accidentels ou ...

Page 36: ......

Page 37: ...municador 43 Licencia de Usuario Final 44 Garantía Limitada 44 NOTA Este documento no incluye la programación del módulo GPRS Ethernet Sección de panel 851 Consulte el documento Hojas de cálculo de programación DSC número de pieza 29007620R004 que se incluye con el comunicador Las instrucciones de instalación de este documento se aplican solamente a los comunicadores GS2060 GS2065 y TL260GS TL265G...

Page 38: ... son las siguientes Los detectores de humo pueden haber sido instalados o ubicados incorrecta mente El humo no puede ser capaz de alcanzar los detectores de humo como cuando el fuego es en la chimenea paredes o techos o en el otro lado de las puertas cerradas Los detectores de humo no pueden detectar humo de incendios en otros niveles de la residencia o edificio Cada incendio es diferente en la ca...

Page 39: ...stringir los accesos no autorizados y los ataques mediante simulaciones o denegación de servicios Seleccione un proveedor de servicios de Internet ISP que tenga servidores o sistemas redundantes alimentación de reserva enrutadores con servidores de seguridad activados y métodos para identificar y protegerse contra ataques de denegación de servicios por ejemplo mediante simulación Notas para usar r...

Page 40: ... línea principal En este modo es necesario enviar señales de alarma simultáneamente por los dos métodos de comunicación Valores nominales Compatibilidad Los productos o componentes de productos que realizan funciones de comunicación sólo cumplirán los requisitos aplicables al equipo de comunicaciones especificados en UL60950 o CAN CSA C22 2 Nº 950 1 equipo de tecnología de información seguridad pa...

Page 41: ...tería de reserva 3 En el soporte de la tarjeta SIM presione suavemente la cubierta hacia la antena PCB en el sentido que indica la flecha del portatarjetas para ABRIR Esto desbloqueará el portatarjetas por la parte más cercana al borde del PCB del comunicador 4 Levante el soporte de la tarjeta SIM desde el lado que no tiene bisagra 5 Introduzca o quite la tarjeta SIM observando la orientación de l...

Page 42: ...el punto de conexión de la antena roscado se puede ver a través del orificio del gatillo del panel c Localice el orificio del tornillo en la pared derecha del panel Consulte la Figura 2 i Alinee el comunicador ensamblado con la pared lateral del panel y usando el tornillo que se proporciona fije el soporte de montaje al panel d Conecte el latiguillo de antena cuatribanda blanco que se suministra a...

Page 43: ...omo PSTN o enrutamiento del comunicador La sección del panel 302 es redundante y la sección 303 es el número de teléfono de respaldo para la sección 301 NOTA El dígito inicial D del número de teléfono para la detección del tono de marcación está progra mado previamente 3 En la sección 350 programe el formato de comunicación como Contact ID 03 o SIA FSK 04 NOTA Si cualquiera de los números de teléf...

Page 44: ...de CA y el conector de la batería al panel El comunicador y el panel se encenderán juntos a Observe que los LED rojo y amarillo del comunicador parpadean a la vez mientras se inicializa Los LED rojo y amarillo continuarán parpadeando hasta que la unidad se haya comunicado correctamente con todos los receptores programados b Si esta es la primera vez que se ha encendido el comunicador el módulo sol...

Page 45: ...ntenga un registro del número de teléfono de la tarjeta SIM si los usuarios lo requieren para las funciones de SMS de Mando y Control Debido a la naturaleza del proceso de activación de la tarjeta SIM con los proveedores de red GSM la activación de la tarjeta puede tardar hasta 24 horas Función de ahorro de energía solo GS2065 TL265 Los modelos GS2065 y TL265GS tienen un modo de ahorro de energía ...

Page 46: ...onal en el comunicador e Conecte uno de los extremos del cable de ampliación de la antena a la radio del comunicador f Vuelva a colocar la cubierta frontal en el panel g Encienda el panel y espere hasta que se inicialice 3 Mueva la antena de extensión a varias ubicaciones mientras observa los dos LED verdes del panel Continúe moviendo la antena de extensión hasta que reciba una cobertura aceptable...

Page 47: ... cíclicos 20 o en la recepción de un MSDI 1 2 7 8 14 El problema se eliminará después de que se ejecuten correctamente los comandos cíclicos y de inicialización y los comandos MIPCALL y MIPOPEN d Cobertura insuficiente El problema se indica si se calcula que la cobertura es demasiado baja Los dos LED verdes APAGADOS El problema se eliminará cuando la cobertura calculada esté por encima de los requ...

Page 48: ...a 5 3 Aplique un puente para comunicar los pines 4 y 5 predeterminados de hardware 4 Quite toda la alimentación del panel y después enciéndalo Espere hasta que los dos LED verdes del comunicador empiecen a parpadear rápidamente Los LED verdes continuarán parpadeando mientras esté conectado el puente 5 Quite el puente de los pines de hardware 4 y 5 Los LED verdes dejarán de parpadear NOTA Ahora el ...

Page 49: ...ección IP válida De lo contrario póngase en contacto con el administrador de la red LED amarillo 7 parpadeos Receptor no disponible Asegúrese de que la vía Ethernet tiene conectividad con Internet ConfirmequeelSIMnotieneunAPNpersonalizado Launidadnopermitirálaconexióna Internet con APN personalizados SiutilizaunadirecciónIPestática asegúresedequelapuertadeenlaceylamáscarade subred se hayan introdu...

Page 50: ...esde que el receptor esté conforme con los términos de este EULA Si el PRODUCTO DE SOFTWARE es una actualización cualquier transferencia debe incluir también todas las versiones previas del PRODUCTO DE SOFTWARE f Término Sin prejuicio de cualesquiera otros derechos DSC puede terminar este EULA si Usted negligencia el cumplimiento de los términos y condiciones de este EULA En tal caso usted debe de...

Page 51: ...tía Las tarjetas o etiquetas de acceso devuel tas para su reemplazo bajo la garantía serán acreditadas o reemplazadas a opción de DSC Los productos no cubiertos por la presente garantía o de otra manera fuera de la garantía debido al transcurso del tiempo mal uso o daño serán evaluados y se proveerá una estimación para la reparación No se realizará ningún trabajo de reparación hasta que una orden ...

Page 52: ......

Page 53: ... the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for help The user may find the following booklet prepared by the FCC useful How to Identify and Resolve Radio Televi sion Interference Problems This booklet is available from the U S Government Printing...

Reviews: