7.4 The COM 1/2 Serial Interface Cable
DT terminal for dual row 0.1" (2.54 mm grid) and 1.27 mm flat cable
2
1
C O M 1
9pin D-Sub
male
C O M 1 / 2
1
6
2
3
4
5
7
8
9
Line of pin 1
9 10
ATTENTION:
-
Do not short-circuit these signal lines.
-
Never connect any pins either to the same plug or to any other plug on the MICROSPACE
PCC-P5. The +/-10Volt will destroy the MICROSPACE core logic immediately. No warranty in this
case!
-
Do not overload the output: max. output current of Maxim converters: 10 mA
-