Table 1–1 (Cont.) Basic Troubleshooting
Symptom
Possible Cause
Suggested Solution
System Problems
The port to which the
terminal connects may
be faulty.
Try connecting the terminal to
another system. If this solution
works, the port to which the
terminal was connected is faulty.
If the terminal still does not
operate, it is faulty. In either
case, contact your Digital services
representative.
The terminal cable may
be faulty.
Connect the terminal cable and
the terminal to another system.
If the connected terminal works,
the DZ circuitry or MMJ connector
is faulty. Otherwise, the cable
is faulty. Contact your Digital
services representative.
The power-up display
contains question marks.
A diagnostic error has
occurred.
See Section 1.4.
The power-up test
display contains
unexpected characters.
The terminal settings
are incorrect or the DZ
circuitry is faulty.
Make sure the terminal settings
are correct, then run the power-
up test again. If the terminal is
set correctly, contact your Digital
services representative.
The system fails to boot
the operating system.
The system defaults are
incorrectly set.
Set the system defaults as
described in the OpenVMS
Factory Installed Software User
Information document, then try
to boot the system again. If
the system still fails to boot,
contact your Digital services
representative.
(continued on next page)
1–4 Troubleshooting and Diagnosing Problems