General Configuration Screen
DLE49-MA User’s Guide
6-17
1.
Use the arrow keys to highlight the Management Mode field:
2.
Use the SPACE bar to toggle the options (DISTRIBUTED or
STAND ALONE) until the desired mode displays.
3.
Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in
Figure 6-6
displays.
4.
Use the arrow keys to highlight the YES command and press ENTER.
The changes are saved and the module reboots.
6.5.11
Configuring the COM Port
The DLE49-MA COM port supports the following applications:
•
Local Management connections
•
American Power Conversion (APC) Uninterruptible Power Supply
(UPS) connections
To configure the COM port, proceed as follows:
1.
Use the arrow keys to highlight the Com field.
Upon saving the new Management Mode, the module will
reboot.
If the module will be set to STANDALONE, ensure the following
procedures have been completed:
The module has been assigned a unique IP address.
The module has been assigned SNMP Community Names
Configuration from the module SNMP Community Names
Configuration screen (
Section 6.6
). In STAND ALONE
management mode, the module does not use the community
names of the DLM6C-AA chassis.
!
Before altering the COM port settings, ensure that a valid IP
address is set for the module or chassis. (Refer to
Section 6.5.1
.) Read this entire COM port configuration section
before changing the settings of the COM port.