outputs to be assigned to different stations and thereby recognized as triggering an action because a
specific station is active. Configure per station used GPIO output relays on the proper station interface
configuration page under
Setup > Decoder > Forwarding
.
GPIO Input 1 alert
programming
A selection menu allows GPIO Input #1 to be programmed to do:
1. Nothing;
2. Forward an active unforwarded decoded alert upon closure;
(Requires Plus Package license)
3. Hold a non-national alert when forwarded or originated until closure;
(Requires Plus Package license)
4. Delay a non-national alert while closed.
GPI Input 2 alert
programming
A selection menu allows GPIO Input #2 can be programmed to do:
1. Nothing;
2. Issue a Required Weekly Test alert (RWT). The FIPS codes used are the same as those used for the
normal One-Button test.
3. Start voice dub EAS alert on closure; subsequent closures skip to EOM.
(Requires Plus Package
license)
GPIO Output 1 Relay
programming
(Programmability requires Plus Packagelicense)
This selection box allows for programming the GPI Output #1 closure. Set according to the condition
that needs to be monitored.
GPIO Output #1 can be programmed to make a contact closure during:
1. EAS audio play-out.
2. Momentary closure at start of EAS Audio play-out.
3. Momentary closure at end of EAS Audio play-out.
4. Momentary closure at start and end of EAS Audio play-out.
5. EAS Video play-out.
GPIO Output 1 Activation Filter Configuration
Choose the FIPS and EAS codes that will control which alerts trigger the applicable programmed GPIO
output 1 relay.
GPI Output 2 Relay
programming
This selection box allows for programming the GPI Output #2 closure. Set according to the condition
that needs to be monitored.