background image

Delete Record

(A) Delete All Record

Please go to the historical record page,  then press and hold key              
         for 2 seconds to delete all record stored in this unit.

(B) Delete Single Record

Press and hold key        for 2 seconds to delete while playing the 
record.

Setting

Setting page can be accessed directly 
through Menu selection.

Date and Time:

Press            to set date and time and         to confirm.  Press      to return 
to the previous step.

Press       to decrease the number.
Press       to increase the number.

Alarm: 

Press           to set the alarm time. Press      to decrease the number.  Press        
     to increase the number.
Please press           to select ON/OFF and      to confirm. Press      to return 
to the previous step.

08

09

Warning: Erased record can not be restored.

&

Summary of Contents for ECG-10X

Page 1: ...ECG EKG Recorder ...

Page 2: ...g Instructions 04 Power on off Measurement Historical Record 07 Review Measurement Record Delete Record Setting 09 Date and Time Alarm Bluetooth 10 Bluetooth Upload record to PC server 11 USB Upload record to PC server 13 Important Safety Note 15 Maintenance and Storage 17 Troubleshooting 18 Warranty Information 19 Manufature Date 19 Specifications 20 ...

Page 3: ...nd period These ECG readings can monitor your condition more easily Cardio care unit is designed for prescription purpose record store and display the ECG waveform and heart rate that it can help doctor to know the patient s condition This unit is intended for use on the adult population over 20 years old NOTE Please note that while the measurement from an ECG EKG recorder is an useful guide for y...

Page 4: ... with a beep sound after 5 seconds Place the unit with the back end electrode against the spot slightly below your chest The measurement will stop after 30 seconds of recording automatically and is accompanied with a beep sound The heart rate will be shown on the page and press D The unit will ask automatically if you want to upload the record to server press to upload or to skip E After selection...

Page 5: ...t Movement including talking coughing or sneezing during measurement can affect the measurement results If the position of your finger or arm is inappropriate during measurement the results may be inaccurate so be sure to check their positions before taking a measurement After taking measurement disinfect the electrodes by wiping them with a soft cloth or cotton swab moistened with disinfectant al...

Page 6: ...rd Setting Setting page can be accessed directly through Menu selection Date and Time Press to set date and time and to confirm Press to return to the previous step Press to decrease the number Press to increase the number Alarm Press to set the alarm time Press to decrease the number Press to increase the number Please press to select ON OFF and to confirm Press to return to the previous step 08 ...

Page 7: ...o2 com before uploading record to PC server Go to http www digio2 com Press Download Press Healthcare Device Press My Cardio Care Download and install My Cardio Care to your PC 2 Setting Device Name 3 Connect Bluetooth When you see the Bluetooth device has been connected then key in 0000 as passkey 4 1 Go to the device s Historical record page Bluetooth Upload record to PC server Users are allowed...

Page 8: ...KG waveform 1 Download My Cardio Care Please download and install My Cardio Care from our website http www digio2 com before uploading record to PC server Go to http www digiO2 com Press Download Press Healthcare Device Press My Cardio Care Download and install My Cardio Care to your PC 2 Turn Off Bluetooth Make sure the Bluetooth of Cardio Care is turned off Press to select ON OFF and to confirm ...

Page 9: ...n their eye and who have an aneurysm clip in their brain Do not attempt self diagnosis or self treatment based on the measurement results and analysis Always consult your doctor Self diagnosis or self treatment may lead to deterioration in your condition Do not use this unit on people with sensitive skin or allergies Do not attempt to use the unit over or through clothing Do not attempt to use the...

Page 10: ...ystem does not provide sufficient insulation to mains and earth however the equipment can be safely connected to other IEC EN 60601 1 approved equipment that has all its connectors intended for connection to this unit separated from earth by basic insulation Do not use this product in combination with non IEC EN 60601 1 approved computers adaptors Any ECG EKG record erased from the unit cannot be ...

Page 11: ...onds of data has been recorded The chest electrode has been applied over clothing Your skin is dry The ECG signal is too weak Replace both batteries with new ones Insert the batteries with their polarities correctly aligned Check the instructions and repeat the measurement Relax and repeat the measurement Make sure that your finger and chest maintain contact with the electrodes for the full 30 sec...

Page 12: ...ence Be sure to read the Instruction Manual for correct installation and use Also be sure to read the Instruction Manuals for all other electronic equipment nearby ECG 10X 1 5V AAA Battery 2 10mm mV 5 10M 2mV 0 005 40 Hz 95 dB 12 bits 256 samples sec 30 sec 125x64x27 144g 20 C 50 C 10 C 40 C 25 95 USB Bluetooth USB Bluetooth 60mm x 32 5mm LCM display panel ECG EKG Specifications Power Supply Stand...

Page 13: ... by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the follow...

Reviews: