Federal Communications Commission (FCC) Statement

15.21

You are cautioned that changes or modifications not expressly approved by the part 

responsible for compliance could void the user’s authority to operate the equipment.

15.105(b)

This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC rules. 

These limits are designed to provide reasonable protection against harmful 

interference in a residential installation.

This equipment generates uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular 

installation. 

If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, 

the user is encouraged to try to correct the interference by one or more of the 

following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the 

following two conditions: 

1) this device may not cause interference and

2) this device must accept any interference, including interference that may cause 

undesired operation of the device.

FCC RF Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an 

uncontrolled environment. 

End users must follow the specific operating instructions for satisfying RF exposure 

compliance. 

This transmitter must not be co-located or operating in conjunction with any other 

antenna or transmitter.

ECG-10X wireless system configuration and operation:

1. Quality of service: BQB test

2. Security requirements: Key in Pin code "0000".

3. If users paired with PC was unsuccessful, the data was not shown it on the LCM. 

Users can repairing and upload the it again.

Summary of Contents for ECG-10X

Page 1: ...ECG EKG Recorder ...

Page 2: ...g Instructions 04 Power on off Measurement Historical Record 07 Review Measurement Record Delete Record Setting 09 Date and Time Alarm Bluetooth 10 Bluetooth Upload record to PC server 11 USB Upload record to PC server 13 Important Safety Note 15 Maintenance and Storage 17 Troubleshooting 18 Warranty Information 19 Manufature Date 19 Specifications 20 ...

Page 3: ...nd period These ECG readings can monitor your condition more easily Cardio care unit is designed for prescription purpose record store and display the ECG waveform and heart rate that it can help doctor to know the patient s condition This unit is intended for use on the adult population over 20 years old NOTE Please note that while the measurement from an ECG EKG recorder is an useful guide for y...

Page 4: ... with a beep sound after 5 seconds Place the unit with the back end electrode against the spot slightly below your chest The measurement will stop after 30 seconds of recording automatically and is accompanied with a beep sound The heart rate will be shown on the page and press D The unit will ask automatically if you want to upload the record to server press to upload or to skip E After selection...

Page 5: ...t Movement including talking coughing or sneezing during measurement can affect the measurement results If the position of your finger or arm is inappropriate during measurement the results may be inaccurate so be sure to check their positions before taking a measurement After taking measurement disinfect the electrodes by wiping them with a soft cloth or cotton swab moistened with disinfectant al...

Page 6: ...rd Setting Setting page can be accessed directly through Menu selection Date and Time Press to set date and time and to confirm Press to return to the previous step Press to decrease the number Press to increase the number Alarm Press to set the alarm time Press to decrease the number Press to increase the number Please press to select ON OFF and to confirm Press to return to the previous step 08 ...

Page 7: ...o2 com before uploading record to PC server Go to http www digio2 com Press Download Press Healthcare Device Press My Cardio Care Download and install My Cardio Care to your PC 2 Setting Device Name 3 Connect Bluetooth When you see the Bluetooth device has been connected then key in 0000 as passkey 4 1 Go to the device s Historical record page Bluetooth Upload record to PC server Users are allowed...

Page 8: ...KG waveform 1 Download My Cardio Care Please download and install My Cardio Care from our website http www digio2 com before uploading record to PC server Go to http www digiO2 com Press Download Press Healthcare Device Press My Cardio Care Download and install My Cardio Care to your PC 2 Turn Off Bluetooth Make sure the Bluetooth of Cardio Care is turned off Press to select ON OFF and to confirm ...

Page 9: ...n their eye and who have an aneurysm clip in their brain Do not attempt self diagnosis or self treatment based on the measurement results and analysis Always consult your doctor Self diagnosis or self treatment may lead to deterioration in your condition Do not use this unit on people with sensitive skin or allergies Do not attempt to use the unit over or through clothing Do not attempt to use the...

Page 10: ...ystem does not provide sufficient insulation to mains and earth however the equipment can be safely connected to other IEC EN 60601 1 approved equipment that has all its connectors intended for connection to this unit separated from earth by basic insulation Do not use this product in combination with non IEC EN 60601 1 approved computers adaptors Any ECG EKG record erased from the unit cannot be ...

Page 11: ...onds of data has been recorded The chest electrode has been applied over clothing Your skin is dry The ECG signal is too weak Replace both batteries with new ones Insert the batteries with their polarities correctly aligned Check the instructions and repeat the measurement Relax and repeat the measurement Make sure that your finger and chest maintain contact with the electrodes for the full 30 sec...

Page 12: ...ence Be sure to read the Instruction Manual for correct installation and use Also be sure to read the Instruction Manuals for all other electronic equipment nearby ECG 10X 1 5V AAA Battery 2 10mm mV 5 10M 2mV 0 005 40 Hz 95 dB 12 bits 256 samples sec 30 sec 125x64x27 144g 20 C 50 C 10 C 40 C 25 95 USB Bluetooth USB Bluetooth 60mm x 32 5mm LCM display panel ECG EKG Specifications Power Supply Stand...

Page 13: ... by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the follow...