DR4024 Servodecoder
P 24
www.digikeijs.com
® R-Bus, B-Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
Stand 2018.10.22
Default 0 (Preset 0) (default)
4 servos (1-4) and 4 separate switching outputs (5-8)
Default seBng 0 automa1cally gives the module 8 addresses.
Addr. 1-4 are used for the 4 servo outputs.
Addr. 5-8 are assigned for the 4 addi1onal switching outputs OUT5 -
OUT8.
Preset 1 (Preset 1)
4 servos (1-4) linked to the switching outputs (1-4
Default seBng 1 automa1cally gives the module 4 addresses (1-4).
The addi1onal switching outputs are linked to the servo outputs. The
addi1onal switching outputs are switched as soon as the respec1ve
servo reaches the middle posi1on.
Use this preset if you want to polarize a crossover via a relay DR4102.
Preset 2 (Preset 2)
4 servos with mass simula1on (1-4)
and 4 separate switching outputs (5-8)
Default seBng 2 automa1cally gives the module 8 outputs.
Addr. 1-4 are assigned for the 4 servo outputs S1-S4, whereby the
mass simula1on is automa1cally ac1vated for each servo output.
Addr. 5-8 are assigned for the 4 addi1onal switching
outputs OUT5 -
OUT8.
_1_
_2_
_3_
_4_
6
7
8
5
1
2
3
4
6
7
8
5
1
2
3
4
7.2 Presets (Preset 1-4)
There are four preset CV sets to make programming easier.
These presets are called with the CV47. The seBng in CV47 automa1cally sets some default effects and seBngs.
It is not possible to read the CV 47.