18
6.4.1 Inputs
The input signals or passage clearance (HAB1 and HAB2) can be originated by a relay
contact, pushbutton contact, tension from 5 to 24 Vca/cc, from 110 to 220 Vca/cc. To
enable passage through relay contact or pushbutton, make the connection as shown
below:
Enabling passage through tension pulse is shown in the image below. It is necessary
to observe the polarity of the Vcc voltages and to use an external resistor for high
voltages (110V and 220V).
6.4.1.1 Connections scheme
5 a 24
Vca ou Vcc
110 a 220
Vca ou Vcc
clip
Output
Relay
Access control board
Inputs
R
etu
rn
sign
a
ls