21
2.4.4 RELAY OUTPUTS
The two relay outputs of the Vega Video allow to activate and deactivate some devices, such as a light, a
siren, etc. Each relay has 3 contacts to connect the device: N.C. (Normally Closed); N.O. (Normally Open);
Common.
To connect your devices, keep in mind the following relay features:
RELAY OUTPUT FEAURES
max V :
•
220 V
max I :
•
2000 mA
max P :
•
60 W
Possible connections :
•
pin 15 – pin 16 (input 1 N.C.)
•
pin 17 – pin 16 (input 1 N.O.)
•
pin 18 – pin 19 (input 2 N.C.)
•
pin 20 – pin 19 (input 2 N.O.)