![Digi ConnectPort X Series User Manual Download Page 128](http://html1.mh-extra.com/html/digi/connectport-x-series/connectport-x-series_user-manual_2496303128.webp)
Configure the device using the Digi ConnectPort X Family web interface
Configuration through the web interface
Digi ConnectPort X Family
128
l
C
is the node type.
In the following table, API mode is a frame-based interface mode that extends the level to
which a host application can interact with the networking capabilities of the module. When
in API mode, all data entering and leaving the module is contained in frames that define
operations or events within the module. Gateways typically use XBee firmware for
coordinator API mode. More information about API mode is in the user manuals for the
XBee RF modules.
AT mode is a state in which incoming serial characters are interpreted as XBee AT
commands. More information about AT mode is in the Product Manuals for the XBee RF
modules.
ZigBee nodes use different firmware for AT and API mode. Standard nodes support both AT
and API modes.
The gateway radio must be ZigBee type 1 or 3, or non-ZigBee type 0.
Remote nodes can use any node type.
The possible node type values are follows:
C
value in filename
Node type
For ZigBee radios (ZNet, ZB, SE):
0
Coordinator AT command mode
1
Coordinator API mode
2
Router AT mode
3
Router API mode
4
Router/End Device Sensor Adapter
5
End Device Power Harvester Adapter
6
Router/End Device Analog I/O Adapter
7
Router/End Device Digital I/O Adapter
8
End Device AT command mode
9
End Device API mode
x
Multiple node types in a zip file