10
inSTaLLaTion
1. Shut off main water supply.
2. Remove the manual stem
from the existing valve and
temporarily remove the
anti-siphon cap (see A).
3. Replace any existing worn
washers with the new ones
provided.
4. Install the actuator with the
controller into the manual anti-siphon valve body by turning actuator clockwise.
tighten firmly, but do not over tighten (see B).
5. turn on main water supply.
6. Splice the solenoid hot wires (red) to the controller color-coded wires
(red). Splice the solenoid white wire to the single incoming black wire.
USE
CONVENTIONAL dry-SpLICE WATErprOOF CONNECTOrS.
Leave slack on
each side of the wires so that repairs, if needed, can be carried out easily.
7. After installation is complete, test each valve in manual mode through the
controller (see section 16 on page 16). Adjust the flow by turning the flow
control knob, making sure that each valve is operating correctly.
8. Program the controller (see section 8 on page 12).
6. usinG a sensor
1. Carefully strip each of the controller’s two yellow sensor wires.
2. Select a normally open sensor, or configure the sensor to be normally open (see
sensor instructions).
3. Connect 1 of each yellow wire from the controller to each of the normally open
wires from the sensor
USING WATErprOOF CONNECTOrS
.
4. When the sensor is active, appears on the display and the sensor will
override the program when triggered.
5. Do not strip or cut the wire if a sensor is not used.
6. Follow the sensor manufacturer’s instructions for calibrating the sensor.
7. Compatible rain sensors: Hunter Mini Click nO and Rain Bird RSD.
anti-Siphon Cap
A
B
manual Stem
Flow control knob