5. installation
5.1 VALVE ANd SOLENOId ASSEMBLy
NOTE:
Suggested operating pressure: 10-120 PSI (.7 to 10.5 BAR)
Use DIG’s DC valve assembly or solenoid model R710DC.
1. Shut off the mainline to the valve.
2. Install the DIG valve and latching solenoid assembly or unscrew the conventional solenoid
from the valve used and remove the solenoid housing, solenoid stem, plunger, spring,
and O-ring (if necessary).
3. Converting SUPERIOR valves: First, remove the SUPERIOR solenoid and O-ring and
replace with one O-ring (DIG part #30-492) inside the solenoid thread cavity (this O-ring
is included). Install the adapter then, slip the manual handle into the adapter. Attach the
solenoid with the plunger and position the handle at a 45° angle towards the valve outlet
(
see B1-C
). this creates a manual lever, helpful for manual on/off. Firmly tighten the
solenoid by hand, but do not over tighten.
4. Converting IRRItROL (HARDIE) valves: Leave Irritrol manual handle in place (not applicable
for 205 series). Screw the provided adapter into Irritrol adapter or directly into valve (205
series only). DO nOt use the orange manual handle provided with this installation. Screw
the R710 DC solenoid with the plunger into the adapter.
5. Converting RAIn BIRD valves: Unscrew and remove Rain Bird AC solenoid. Install adapter
model P00-996 into a Rain Bird valve and tighten the adapter with a wrench. next, install
the R710DC latching solenoid directly into the adapter clockwise and hand tight. DO nOt
use the adapter with the orange handle provided.
5
45°
Additional system components
45°
Additional system components
45°
Additional system components
45°
Additional system components
a
b
b1
c
6.
Splice the solenoid hot wires (red) to the single station controller color-coded
wires (red).
Splice the solenoid black wire to the single incoming white wire.
r