background image

OPERATOR’S MANUAL

Dj ASM II Air Seeder Monitor

11001-1311-200501

SYSTEM OPERATION / 17

Figure 22
Example of Module 5 Error

A Module 5 Communication error is similar to the 8 Vdc error. The “C” and 
“5” will toggle back and forth. The error cannot be eliminated until the 
communications failure has been corrected and power has been cycled 
OFF/ON.

Figure 23
Example of Communications Error

The error “C/A” indicates the monitor is experiencing communication 
problems with all modules. The letters “C” and “A” will toggle back and forth. 
This occurs, for instance, when the monitor is powered up with no modules 
connected.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Alarm

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Alarm

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Summary of Contents for DjASM II

Page 1: ...OPERATOR S MANUAL...

Page 2: ...5 Hopper Level Low 15 Errors 16 Troubleshooting Guide 19 Unit Will Not Power On No LEDs Will Light During The Power Up Sequence 19 Row Or Hopper Indicator Fail To Illuminate After Self Test 19 Rows Fa...

Page 3: ...Dj ASM II Air Seeder Monitor 11001 1311 200501 ii...

Page 4: ...ty 8 ASM II module scanning capability 16 row display capability per ASM II Module or 15 rows and 1 hopper level sensor Implement lift switch input 16 row indicators 7 segment indicator displays 1 2 3...

Page 5: ...ional Module power is not carried through the console due to worst case voltage drop on 128 row system P2 is not required for systems with four modules or less 64 rows or less P1 can drive four module...

Page 6: ...n dimming and alarm silencing Figure 3 Console Mounting Before drilling assure the power and main hitch harness can be routed in the proper manner Harness retention and routing outside of the cab is a...

Page 7: ...he monitor operates on 12Vdc only The red fused lead should be connected to the positive battery terminal and the black lead should be connected to the negative battery terminal ASM II CONSOLE MAIN HA...

Page 8: ...r assuring the connector will reach the implement connector at the hitch MODULE MOUNTING Lay out all harnesses and modules on the implement to determine proper mounting locations Refer to Figure 2 for...

Page 9: ...II Air Seeder Monitor 11001 1311 200501 6 INSTALLATION Figure 6 Module Mounting Before drilling assure the harness can be routed in the proper manner Consider harness placement in regard to air seeder...

Page 10: ...letter O will be displayed as well as the odd row indicators Release the switch immediately Figure 8 Odd Row Enable MINIMUM SEEDING RATE The Minimum Seeding Rate feature allows for setting a minimum n...

Page 11: ...1 1 every 6 seconds 6 16 seeds every second 12 1 every 5 seconds 7 20 seeds every second 13 1 every 4 seconds 8 30 seeds every second 14 1 every 3 seconds 9 40 seeds every second 15 1 every 2 seconds...

Page 12: ...L Dj ASM II Air Seeder Monitor 11001 1311 200501 SYSTEM CONFIGURATION 9 ENGLISH CONVERSION FOR SEEDING RATE sps 43560 x V 5280 3600 x S 12 P population seeds acre V speed m p h S spacing inches sps th...

Page 13: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 10 SYSTEM CONFIGURATION...

Page 14: ...the sensor detection The Module Number will display 1 and the row numbers with detected sensors will illuminate If another Dj ASM II module is connected the Module Number will advance to 2 and the ro...

Page 15: ...onnected or has failed on module 1 Figure 13 Example of Failed Row Figure 14 illustrates that no rows are lit on the Hopper detection sequence This indicates that a Hopper module was detected but no H...

Page 16: ...7 segment display will scan through each detected module number Figure 15 Planting Display No Failed Rows SINGLE ROW FAILURE If a single row failure is detected the appropriate Module Number will be d...

Page 17: ...row numbers for 2 seconds on each module For example if Module 1 Row 8 and Module 2 Row 5 fail the following display sequence will occur and loop Figure 17 Example of Multiple Row Failure The looping...

Page 18: ...sound for 2 seconds LIFT SWITCH The lift switch input will keep the ALL ROWS FAILURE from occurring When the Lift Switch input is grounded it is considered active inhibits ALL ROWS FAILURE When activ...

Page 19: ...d Figure 21 Example of Module 5 Start Up Error This error CANNOT be disabled using the Alarm Cancel feature The problem must be either repaired or the module must be disconnected from service The othe...

Page 20: ...has been corrected and power has been cycled OFF ON Figure 23 Example of Communications Error The error C A indicates the monitor is experiencing communication problems with all modules The letters C...

Page 21: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 18 SYSTEM OPERATION...

Page 22: ...ect implement main harness Measure for short between red power and black ground wires If shorted the power harness or the console is faulty and requires repair or replacement Contact your Parts and Se...

Page 23: ...treatments require scrubbing with water and a commercial cleanser 3 Check module harness connections at the module and sensors Check module harness for pinched worn or broken elements Check sensor cab...

Page 24: ...se the harness or monitor is faulty Check module harness for pinched worn or broken elements Check sensor for pinched worn or broken wires 4 Assure hopper is connected to ROW 16 HOPPER connector input...

Page 25: ...h module Corrective Action 1 Lost communication with module Check indicated module number first and nearby modules next Check all communications next by each module for its sensors UNIT DISPLAYS A C F...

Page 26: ...ness 46775 1330S1 12 row harness 7 5 row spacing 46775 1300S1 12 row harness 15 row spacing 46775 1301S1 12 row harness 30 row spacing 46775 1302S1 16 row harness 7 5 row spacing 46775 1310S1 16 row h...

Page 27: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 24 DJ ASM II SERVICE PARTS...

Page 28: ...defect is discovered DICKEY john will at our option either replace or repair said part This warranty does not apply to damage resulting from misuse neglect accident or improper installation or mainten...

Reviews: