OPERATOR’S MANUAL
Dj ASM II Air Seeder Monitor
11001-1311-200501
SYSTEM OPERATION / 11
SYSTEM OPERATION
POWER SEQUENCE
Moving the I-O (power) switch to the center position turns on the monitor.
Upon power up, the Air Seeder Monitor provides the operator with an
indicator test by illuminating all 16 rows and the 7 display segments. The
alarm will output a single chirp during the display test.
Figure 11
Power Up Indicator and Alarm Test
SENSOR DETECTION
After the indicator test is complete, the monitor will begin displaying the
results of the sensor detection. The Module Number will display “1” and the
row numbers with detected sensors will illuminate. If another Dj ASM II
module is connected, the Module Number will advance to “2” and the row
numbers with detected sensors will illuminate, and so on for additional
modules. The monitor will dwell for 2 seconds on each module. In the event
a hopper/row module is connected, the monitor will display the seed
sensors detected first, then detect the hopper, with an “H” displayed.
The following sensor detection sequence, Figure 12, depicts 56 rows of
monitoring with 12 rows connected to Dj ASM II module 1, 16 rows
connected to modules 2 and 3, and 12 rows and 1 hopper connected to
module 4.
Chirp
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Summary of Contents for DjASM II
Page 1: ...OPERATOR S MANUAL...
Page 3: ...Dj ASM II Air Seeder Monitor 11001 1311 200501 ii...
Page 13: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 10 SYSTEM CONFIGURATION...
Page 21: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 18 SYSTEM OPERATION...
Page 27: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 24 DJ ASM II SERVICE PARTS...