Test y Ajustes
42
4.32 TOWA Protocol
Protocol
1.Command mode:
There are three different formats depending on the command send by
the cash register:
FORMAT 1
Cash Register
Scale
Eq
Cash Register
Scale
AK
Cash Register
Scale
DC1
Cash Register
Scale
SH SX S SIGN W5 W4 W3 W2 W1 W0 UN1 UN0 BCC EX ET
FORMAT 2
Cash Register
Scale
Eq
Cash Register
Scale
AK
Cash Register
Scale
DC2
Cash Register
Scale
SH
SX P7 P6 P5 P4 P3 P2 P1 P0 BCC EX
SX S SIGN W5 W4 W3 W2 W1 W0 UN1 UN0 BCC EX
SX U7 U6 U5 U4 U3 U2 U1 U0 BCC EX ET
FORMAT 3
Cash Register
Scale
Eq
Cash Register
Scale
AK
Cash Register
Scale
DC3
Cash Register
Scale
SH
SX P7 P6 P5 P4 P3 P2 P1 P0 BCC EX
SX S SIGN W5 W4 W3 W2 W1 W0 UN1 UN0 BCC EX
SX U7 U6 U5 U4 U3 U2 U1 U0 BCC EX ET
Note
:
-
On the format 3 the scale transmit the data continuously every second