Test y Ajustes
24
4.15 KABEL cash register protocol
Protocol
Cash Register
Scale
S
X
WE
X
(D
3
zD
4
) ó (D
3
uD
4
)
S
X
WWW.WWWxE
X
D
3
zD
4
Weight cancellation frame
Cash Register
Scale
S
X
cE
X
Where:
S
X
:
0x02h
z:
0x7Ah
E
X
:
0x03h
u:
0x75h
D
3
:
0x13h
W:
0x57h
D
4
:
0x14h
WWW.WWW:
6 characters for weight
c:
0x63h
NOTE:
-
The scale sends the weight when the total key is pressed.
-
If you want to cancel a sent weight it is possible pressing one key (undefined) on the scale. The scale
will send a cancellation command. This is the same command (0x63) that the cash register sends
when the key C is pressed.
-
Once the scale sends the frame
S
X
WE
X
, a timeout of 500 milliseconds is set to receive
D3zD4
or
D3uD4
. If this timeout expire the scale does not send the weight.
-
If the weight is out of range, the scale will not send the weight frame.
-
If the weight is unstable or negative, the scale waits until it has stable and positive weight.
Contact with the technical support department for more information.