DA 62 AFM
Handling, Care,
Maintenance
The control surfaces gust lock is installed as follows:
1. Move the rudder pedals to the middle position.
2. Engage the control surfaces gustlock with the pedals.
3. Engage the stick, wrap straps around stick once.
4. Attach the locks.
5. Wrap the strap under the lower rail of the rudder pedal assy and attach the
lock on the gust lock.
CAUTION
Do not wrap the strap around the spindle.
6. Tighten all straps.
For removal reverse the sequence.
Doc. No. 11.01.05-E
Rev. 0
11-Jan-2019
Page 8 - 9