Abnormal Operating
Procedures
DA 62 AFM
CAUTION
When switching the external power unit ON, the electrically
driven hydraulic gear pump may activate itself for 5 to 20
seconds in order to restore the system pressure. Should the
pump continue to operate continuously or periodically,
terminate flight. There is a malfunction in the landing gear
system.
NOTE
When switching the external power unit ON, all electrical
equipment, connected to the LH and RH main buses is
powered.
17. G1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wait until power-up completed.
Press
ENT
on
MFD
to
acknowledge.
NOTE
The engine instruments are only available on the MFD after
item 17 has been completed.