Diamond H2O  

N1022 Quality Drive     /     PO Box 170     /     Greenville, WI  54942 

Ph: (920) 757-5440 / (866) 757-9287 / Fax: (920) 757-5819 

 

5.

 

CONTROL VALVE INSTRUCTIONS continued 

 

5.3.

 

CONTROL VALVE FUNCTION AND CYCLES OF OPERATION 

 

This glass filled Noryl1 (or equivalent) fully automatic control valve is designed as the primary 

control center to direct and regulate all cycles of a downflow regeneration water softener or filter. 

The time clock control valve can be set to perform downflow regeneration or simply backwash.  The 

time clock control valve has two calendar options for regeneration frequency: 

 

 

An option where the user can choose the number of days (1-99) between each regeneration; 

 

 

A seven-day option where the user can choose which day(s) of the week a regeneration should 

occur. 

 

The control valve is compatible with a variety of regenerants and resin cleaners.  The control valve is 

capable of routing the flow of water in the necessary paths to regenerate or backwash water 

treatment systems.  The injector regulates the flow of brine or other regenerants.  The control valve 

regulates the flow rates for backwashing, rinsing, and the replenishing of treated water into a 

regenerant tank, when applicable. 

 

The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts 

and snap type latches are used.  Caps and nuts only need to be firmly hand tightened because radial 

seals are used.  Tools required to service the valve include one small blade screw driver, one large 

blade screw driver, pliers and a pair of hands.  A plastic wrench is available which eliminates the 

need for screwdrivers and pliers.  Disassembly for servicing takes much less time than comparable 

products currently on the market.  Control valve installation is made easy because the distributor 

tube can be cut ½” above to ½” below the top of tank thread.  The distributor tube is held in place 

by an O-ring seal and the control valve also has a bayonet lock feature for upper distributor baskets. 

 

The AC adapter comes with a 15 foot power cord and is designed for use with the control valve.  The 

AC adapter is for dry location use only.  The control valve maintains timekeeping for up to 8 hours if 

the power goes out and the battery is not depleted.  After 8 hours, the only item that needs to be 

reset is the time of day; valve status and programming are permanently stored in the nonvolatile 

memory.  If a power loss lasts less than 8 hours and the time flashes on and off, the time of day 

should be reset and the non-rechargeable battery should be replaced. 

 

The user can initiate manual regeneration.  The user has the option to request the manual 

regeneration at the delayed regeneration time or to have the regeneration occur immediately. 

Simultaneously press the 

 and 

 buttons to start a regeneration at the next delayed regeneration 

time.  If a regeneration is to occur today an arrow will point to REGEN.  For immediate regeneration, 

simultaneously press and hold the 

 and 

 buttons for three seconds. 

 

When in regeneration, step through the different regeneration cycles by pressing the

 or 

▼ 

buttons. 

 

 

Page 7 

Summary of Contents for DCF6-100-100

Page 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ACTIVATED CARBON WATER FILTER SYSTEM DCF6 SERIES...

Page 2: ...TO SET TIME OF DAY 6 5 2 TO SET TIME OF REGENERATION AND DAYS BETWEEN REGENERATION 6 5 3 CONTROL VALVE FUNCTION AND CYCLES OF OPERATION 7 5 4 OEM GENERAL INSTRUCTIONS 8 5 5 OEM SYSTEM SETUP 8 5 6 USE...

Page 3: ...ia 1 1 5 2 2 5 Gravel 20 10 10 20 25 Inlet Outlet 1 NPT 1 NPT 1 NPT 1 NPT Drain 3 4 NPT 3 4 NPT 3 4 NPT 3 4 NPT Service Rate 3 GPM 5 GPM 8 GPM 10 GPM Backwash Rate 5 3 GPM 5 3 GPM 6 5 GPM 7 5 GPM Heig...

Page 4: ...ted in the Systems Specification table contact Diamond H2O for the correct amount NOTE The control valve and bypass are designed to accommodate minor plumbing misalignments but are not designed to sup...

Page 5: ...control valve onto the tank Make sure that the distributor slides easily into the riser O ring and does not bind or cut the O ring 12 Tighten down the control valve and verify that the orientation is...

Page 6: ...during Backwashing The wires with connectors can be located coming out the back of the control valve These wires connect with the RO controller to prevent RO start up 4 GENERAL START UP INSTRUCTIONS...

Page 7: ...to prevent the media from being flushed into the drain 7 Once all of the air has been purged and you have a constant steady flow of water to the drain completely open the manual inlet valve Allow the...

Page 8: ...icator Press SET to go to the next step 3 Adjust minutes with or buttons 4 Press SET to complete and return to normal operation 5 2 TO SET TIME OF REGENERATION AND DAYS BETWEEN REGENERATION For initia...

Page 9: ...lude one small blade screw driver one large blade screw driver pliers and a pair of hands A plastic wrench is available which eliminates the need for screwdrivers and pliers Disassembly for servicing...

Page 10: ...ay Any changes made prior to the five minute time out are incorporated To quickly exit Installer Displays Settings or OEM Setup simultaneously press SET and Any changes made prior to the exit are inco...

Page 11: ...Times for Different Programs Program All times in Minutes C1 1st Backwash C2 Regenerate C3 2nd Backwash C4 Rinse C5 Fill P0 3 50 3 3 1 99 P1 8 50 8 4 1 99 P2 8 70 10 6 1 99 P3 12 70 12 8 1 99 P4 10 50...

Page 12: ...pressure switch is installed and actuated for 2 minutes A regeneration will occur immediately if no arrow points at Regen Time or A regeneration will occur at the delayed regeneration hour if an arrow...

Page 13: ...et the number of days between regenerations The allowable range is 1 to 99 Press SET to exit Installer Displays and Settings INSTALLER DISPLAYS SETTINGS 7 Day Option STEP 1I7 From normal mode press SE...

Page 14: ...nts to Regen If the arrow does not point to Regen a regeneration will not occur on Wednesday Press SET to go to STEP 9I7 STEP 9I7 Thursday Regeneration To regenerate on Thursday use or until the arrow...

Page 15: ...between displays as desired If the system has called for a regeneration that will occur at the preset time of regeneration the arrow will point to Regen 5 6 2 REGENERATION MODE Typically a system is...

Page 16: ...will begin to regenerate immediately The request cannot be cancelled Note For softeners if brine tank does not contain salt fill with salt and wait at least two hours before regenerating 5 6 4 SET TI...

Page 17: ...h density with a balanced pore structure for more efficient adsorption One of the most common applications for High Activity Carbon HAC is the reduction of the undesirable tastes and odors present in...

Page 18: ...7 SPARE PARTS LIST VALVE SIZE ITEM PART NUMBER 1 1 Battery 3 volt lithium coin cell Type 2032 1 1 Motor Assembly V3107 01 1 1 PC Board 4 Digit V3818TC 1 1 AC Adaptor 110V 12V V3186 1 1 O ring 228 V313...

Reviews: