6.11.2
RDCRC – Remote Data Centre Continuous Record Change
Synopsis
This command changes the parameters for a continuous record collection for which collected data is
transferred via Ethernet to a Remote Data Centre (RDC).
The period is the maximum amount of time allowed before the transfer of a block of continuous records must
be performed.
The label is used as the directory name on the RDC that the files are written to.
Syntax
RDCRC:
RECORD
=,[
PERIOD
=,][
MINREC
=,][
RDC1
=,][
RDC2
=,][
LABEL
=];
Prerequisites
•
The record must already be initiated.
•
If specified,
RDC1
must already be initiated.
•
If specified,
RDC2
must already be initiated
•
If specified,
RDC2
must not equal
RDC1
.
Limitations
•
Before transfer to a RDC can take place, the directory (represented by the label) must exist on the
remote site.
•
PERIOD
must be in the range 30 seconds to 30 minutes.
Attributes
CONFIG
Examples
RDCRC:
RECORD
=1,
PERIOD
=00:05:00,
MINREC
=100,
RDC1
=1,
LABEL
=ALARM;