![Dialogic SS7G2X User Manual Download Page 51](http://html1.mh-extra.com/html/dialogic/ss7g2x/ss7g2x_user-manual_2493101051.webp)
51
Dialogic
®
SS7G2x Signaling Server SGW Mode User Manual Issue 4
6.5.5
CNMOI – Configuration Monitor Initiate
Synopsis
This command initiates the monitoring of an object on the Signaling Gateway. An object is currently a
C7LINK
.
For signaling, the
STS
monitors information sent from the
EQU
of the signaling link and the
RTS
monitors
information received by the signaling link.
Syntax
CNMOI:
C7LINK
=,
STS
=,
RTS
=;
Prerequisites
•
If specified, the
C7LINK
has already been initiated and must have a
TS
and
EQU
.
•
The
PCM
on which
STS
exists must have already been initiated and STS must be within the correct range
for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).
•
The
PCM
on which
RTS
exists must have already been initiated and RTS must be within the correct range
for the PCM type (0 to 31 for E1 and 1 to 24 for T1 PCMs).
•
STS
is not already assigned elsewhere on the system for output.
•
RTS
is not already assigned elsewhere on the system for output.
•
A signaling link can only be monitored once.
Attributes
CONFIG
Examples
CNMOI:
C7LINK
=1,
STS
=3-3-15,
RTS
=5-3-16;
6.5.6
CNMOE – Configuration Monitor End
Synopsis
This command ends the monitoring of an object. An object is currently only an signaling link.
Syntax
CNMOE:
C7LINK
=;
Prerequisites
•
The
C7LINK
is being monitored.
Attributes
CONFIG
Examples
CNMOE:
C7LINK
=1;