Addendum B—Configuring the D/42JCT or
D/82JCT for Your Station Set Emulation
By default, the
Dialogic Configur
ation Manager sets the parameter
PBXSwitch
to
Nortel_Norstar. You must change this parameter to the appropriate PBX type you are integrating
with OneBox.
To program the Dialogic Configuration Manager…
1. On the Start menu at the OneBox platform, select
Programs
|
Dialogic System
Release
|
Configuration Manager-DCM
.
2. Stop the Dialogic service if it is running.
3. Double-click the first installed D/42 or D/82 linecard to open the Properties sheet.
4. On the Miscellaneous tab, select the
PBXSwitch
parameter.
5. In the Values box, select the appropriate PBX type for your station set emulation
integration.
NOTE
For more information, refer to the Integration Technical Note that is specific to the
Station Set Emulation integration you are installing.
6. On the Telephony Bus tab, verify that the correct PCM encoding scheme is selected.
The default value is automatic or U-Law; you must change this value to A-Law outside of
the U.S. and Japan.
7. Click
OK
to close the Properties sheet.
8. Repeat steps 3 through 7 for each installed D/42 or D/82 linecard.
9. Restart the Dialogic service and close Dialogic Configuration Manager.