FS 12‐100‐1/2 M G8‐B8‐E Manual
Technical Data
Page 4
di‐soric GmbH & Co. KG
1
Technical Data
Table 1 : General technical data
Sensing channels
FS 12‐100‐2 M G8‐B8‐E: 2 Sensing channels
FS 12‐100‐1 M G8‐B8‐E: 1 Sensing channel, 1 Internal
stab. channel
Drift stabilization
CROMLASTAB®, Can be switched off
Receiving detector
Three range photo diode
Sensitivity
Adjustable by user
Sensitivity steps
8 (1x, 4x, 20x, 40x, 80x, 200x, 400x, 800x)
Receiving signal resolution
3 x 4096 steps
Object illumination
Power white light LED
Adjustable (4096 Steps)
Can be switched off
Ambient light compensation
Can be switched off
Standard interfaces
12 Switching outputs
2 Control inputs
Serial (RS‐232)
USB
Optional field bus interfaces
Profibus
Fast Ethernet
Profinet
Displays
19 LEDs for outputs and status
Buttons
3 Buttons for Teach‐In
Color resolution (L*a*b*)
∆E
Lab
≤ 1
Response time
≥ 50 µs (limited functionality)
Off‐Delay (channel specific)
0 ms ... 65535 ms
On‐Delay
0 ms ... 65535 ms
Hysteresis
0 % ... 255 %
Color value memory cells
350
Color output channels
12 (up to 350 at binary encoding)
Protection standard
IP54
Power supply
18 ... 28 VDC, max. 500 mA
Case temperature for operation
‐10 °C ... 55 °C
Coupling in signal path
Via optical fiber
Optical fiber adaption
M18x1
Housing material
Aluminum, anodized
Housing size
100 mm × 70 mm × 30 mm
Weight
Ca. 260 g