Ethernet
FS 12‐100‐1/2 M G8‐B8‐E Manual
di‐soric GmbH & Co. KG
Page 13
Update of sensor outputs.
Command:
<IN0001\CR\LF>
The trigger inputs (TRG0 and TRG1) are edge‐controlled. They have to be reset after setting. In the
example above, <IN0000\CR\LF> must be sent afterwards.
To use the trigger inputs, the mode "Ext.Trig", "Ext. Teach" or "Ext. Teach & Trig." must be set via
the FS‐Tool.
SP
With the SP (Store Parameters) command, all parameters are stored in the sensor permanently.
The saving process takes about 2 seconds. During this time the sensor will not respond on the
Ethernet interface, RS232 or USB.
RP
With the RP (Read Parameters) command all permanently stored parameters are loaded into the RAM. All
sensor parameters will be overwritten.
0
4
8
12
3
7
11
15
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
0
0
3
0
6
TR
G
0
TR
G
1
Te
a
c
h
-I
n
-M
o
d
u
s
MS
B
LS
B
Tabellenindex [1 .. 255]*
reserviert