Figure 2-14 - Electrical & Environmental Layout for DRASH Complex
013.01 System Plenum Installation
The DRASH System Plenum provides even distribution of heated or cooled air through the shelter. Refer to the Electrical
and Environmental Plan and the System Diagram for complete detail.
A System Plenum includes the following standard components:
2 - Plenums
2 - Sets flexible ducting with booster fans
1 - Connecting plenum
To install the System plenum, perform the following steps:
1.
Remove the two larger plenums from the bag.
2.
Slip the plenums over the supply duct until the first hook on the plenum reaches the looped keeper closest to the port.
3.
Secure the plenum to the duct with the provided cord.
4.
Along the length of the plenum there are white hooks. Attach these hooks to the corresponding looped keepers.
5.
The air flow through the plenum may be regulated by adjusting the openings with the drawstring.
6.
Attach the second plenum using same method.
7.
To attach the connecting plenum to the third shelter, attach the white hooks to the corresponding looped keepers.
8.
Locate the end of the flexible ducting with the booster fan installed.
9.
Use the Velcro strips to secure the open end of the plenum to the fan.
10.
Secure the flexible ducting with the two (2) white hooks.
11.
Slip the open end of the flexible ducting into the connecting plenum and secure with strap.
ENVIRO NMENTAL
CONTROL UNIT
UST HP-4 T RAI LE R
DIESEL
GENERATO R
SET
DRASH
CARGO
AREA
MODEL 6
MODEL 2
MODEL 6
DOO RWAY
ENTRANCE
ENTRANCE
CONNECTING PLENUM
DOO RWAY
DOO RWAY
DOORWAY
LIG HT LEAD 11'
3 PE R SYSTEM
INTERIOR LEAD 15'
3 PER SYSTEM
S CREEN
WINDOWS
AI R CO NDITI ONI NG
PLENUM
FLUORESCENT LIG HTING
12 LIGHTS PER SYSTEM
FLEXIBLE DUCTI NG (6 IN DIA.)
2 PER SYSTEM
BOOSTER FAN
2 P ER SYST EM
ON E 5 0 FT. T RA IL ER -TO- TR AIL E R ELE C TR ICA L LEA D (11 0 VA C )
TW O 30 F T. TR AIL E R -TO-TR A ILER E L EC TR IC AL L E AD (1 10 VA C )
TW O SUP PL Y D U CT ING ( 25 FT. L ON G W ITH 1 2 IN . D IAME TE R)
TW O R ET UR N D UC TIN G (2 5 F T. L ONG W ITH 12 IN . D IA MET ER )
GA NG O UT LET BOX & SU R GE S U PP RE SS OR
(TH R EE 4- OUT L ETS & FO U R 2 - OUT LE TS P ER SY ST EM)