WATER LEVEL ADJUSTMENT
The water level of all baths can be adjusted by changing the switch settings on the
electronic pressure sensor. Vended washers are shipped with the pressure sensor
harness connected to Switch #1 and factory set for an energy-efficient water level.
Switch #2 is factory set for the classic water level. To use Switch #2, move the org/yel
wire from the terminal marked 21 to the terminal marked 31 and move the red wire
from the terminal marked 22 to the terminal marked 32.
Water level adjustments can also be made in 6mm (1/4”) increments by adjusting the
switch positions for the desired level. It is not recommended for the water level to be
set above the factory Switch #2 settings. Refer to the following chart for the switch
settings and the factory default settings:
Pos 1
Pos 2
Pos 3
Pos 4
Pos 5
Pos 6
5.00
(127)
off
off
off
off
off
off
5.25
(133)
on
off
off
off
off
off
5.50
(140)
off
on
off
off
off
off
5.75
(146)
on
on
off
off
off
off
6.00
(152)
off
off
on
off
off
off
T-300
5.25
(133)
7.00
(178)
6.25
(159)
on
off
on
off
off
off
T-350
5.25
(133)
6.25
(159)
6.50
(165)
off
on
on
off
off
off
T-350 SWD
5.25
(133)
6.25
(159)
6.75
(171)
on
on
on
off
off
off
T-400
7.00
(178)
9.00
(229)
7.00
(178)
off
off
off
on
off
off
T-450
6.00
(152)
6.25
(159)
7.25
(184)
on
off
off
on
off
off
T-450 SWD
5.00
(127)
7.00
(178)
7.50
(191)
off
on
off
on
off
off
T-600
7.25
(184)
9.25
(235)
7.75
(197)
on
on
off
on
off
off
T-650
6.50
(165)
8.25
(210)
8.00
(203)
off
off
on
on
off
off
T-750
6.00
(152)
7.50
(191)
8.25
(210)
on
off
on
on
off
off
T-750 SWD
9.25
(235)
11.75
(298)
8.50
(216)
off
on
on
on
off
off
T-900
6.00
(152)
7.50
(191)
8.75
(222)
on
on
on
on
off
off
T-950
6.00
(152)
7.50
(191)
9.00
(229)
off
off
off
off
on
off
T-1200
6.00
(152)
7.50
(191)
9.25
(235)
on
off
off
off
on
off
T-1450
6.75
(171)
7.00
(178)
9.50
(241)
off
on
off
off
on
off
9.75
(248)
on
on
off
off
on
off
10.00
(254)
off
off
on
off
on
off
10.25
(260)
on
off
on
off
on
off
10.50
(267)
off
on
on
off
on
off
10.75
(273)
on
on
on
off
on
off
11.00
(279)
off
off
off
on
on
off
11.25
(286)
on
off
off
on
on
off
11.50
(292)
off
on
off
on
on
off
11.75
(298)
on
on
off
on
on
off
12.00
(305)
off
off
on
on
on
off
12.25
(311)
on
off
on
on
on
off
12.50
(318)
off
on
on
on
on
off
12.75
(324)
on
on
on
on
on
off
13.00
(330)
off
off
off
off
off
on
13.25
(337)
on
off
off
off
off
on
13.50
(343)
off
on
off
off
off
on
13.75
(349)
on
on
off
off
off
on
14.00
(356)
off
off
on
off
off
on
14.25
(362)
on
off
on
off
off
on
14.50
(368)
off
on
on
off
off
on
14.75
(375)
on
on
on
off
off
on
15.00
(381)
off
off
off
on
off
on
Model
Water Level Chart
Factory Settings:
Switch Positions:
Vended
Switch #1 Efficient
Inches (mm)
Switch #2 Classic
Inches (mm)
Depth inches (mm):
Summary of Contents for T-300 VENDED
Page 4: ...8514 302 001 REV B page 4...
Page 5: ...8514 302 001 REV B page 5...
Page 6: ...8514 302 001 REV B page 6...
Page 31: ...8514 302 001 REV B page 31 The figure below shows the sub menu options for Cycles...
Page 34: ...8514 302 001 REV B page 34 The figure below shows the sub menu options for Plus Cycle Options...
Page 37: ...8514 302 001 REV B page 37 The figure below shows the sub menu options for Settings...
Page 39: ...8514 302 001 REV B page 39 The figure below shows the sub menu options for Usage...