8514-302-001 REV B page 20
PLUMBING
Water supply hoses are furnished with each machine. The threaded connections on the
hoses are ¾-14 BSP.
Separate hot and cold water lines must be provided, maintaining 207 kPa to 827 kPa (30
psi to 120 psi) water flow pressure. A 60C (140F) degree hot water supply is
recommended for best washing results. Do not exceed 82C (180F) degree water
temperature.
DRAIN
The drain outlet tube at the rear of the machine is 57 mm (2 ¼ inches) in diameter. Any
drain hose used must be lower than the drain valve to assure proper draining.
ELECTRICAL
WARNING
SHUT OFF POWER AND WATER BEFORE OPENING ANY SERVICE PANELS.
The Dexter single phase 230VAC 50 Hz washing machines are intended to be permanently
installed appliances. No power cord is provided. The machine should be connected to an
individual branch circuit not shared by lighting or other equipment. A means for
disconnection with a contact separation of at least 3 mm must be provided. The
connection should be sheathed in liquid tight flexible conduit, or equivalent, with
conductors of the proper size and insulation. The sheath of the supply cord must be at
least equivalent to that of a cord complying with IEC 227 or IEC 245. A qualified technician
should make such connections in accordance with the wiring diagram. (Suggest a minimum
wire size of 3.5 mm
2
)
TO MAKE ELECTRICAL CONNECTIONS: Disconnect all power to the washer. Remove the
top panel of the washer and locate the power terminal block near the back of the control
compartment.
Locate the power terminal block and connect L1, N, and Earth as marked.
It is important that the earthing screw next to the power terminal block TB-1 be
connected to a good external earth.
FUSING REQUIREMENTS
15 AMP TIME-DELAY (DUAL ELEMENT) FUSE (or equivalent circuit breaker)
Summary of Contents for T-300 VENDED
Page 4: ...8514 302 001 REV B page 4...
Page 5: ...8514 302 001 REV B page 5...
Page 6: ...8514 302 001 REV B page 6...
Page 31: ...8514 302 001 REV B page 31 The figure below shows the sub menu options for Cycles...
Page 34: ...8514 302 001 REV B page 34 The figure below shows the sub menu options for Plus Cycle Options...
Page 37: ...8514 302 001 REV B page 37 The figure below shows the sub menu options for Settings...
Page 39: ...8514 302 001 REV B page 39 The figure below shows the sub menu options for Usage...