8514-302-001 REV B page 29
The figure below shows the sub menu options for Temp Pricing:
Cycles Option:
This option allows the user to set the bath time and spin time for the “Wash” bath. It
also allows the user to set bath time, water temperature and spin time for “Rinse” and
“Final rinse” baths. (Water temperature for the “Wash” bath is chosen by the customer
using the “Hot”, “Warm” and “Cold” buttons on the front of the machine). For the
“Final Spin” it also allows the user to set the spin speed (see additional description
below).
It also allows the user to return the values to factory defaults. To reset all values in the
Cycles option to factory default, press “Enter” when the “DEFAULT” prompt is shown.
Press “Enter” again when the “RESET” prompt is shown to confirm the action.
1.
“Final Spin” is the spin that occurs after all selected baths & intermediate spins
have been completed. It is a higher spin speed than previously occurring
intermediate spins. The benefit of this higher spin speed is that more water is
extracted from the wash load, which minimizes the drying time needed.
However, in some cases, if the Dexter installation guidelines are not followed
properly, it may be necessary to reduce the spin speed of the “Final Spin”.
The “Final Spin” can be adjusted in increments of 10 G for washers with 90 or
100G maximum spin speed and increments of 20 G for washers with a 200G
maximum spin speed. The factory default “Final spin” speeds are the maximum
values.
Model
Adjustable Final Spin
Range
T-300*
60G to 90G
T-350** or T-350 SWD
60G to 180G
T-400
60G to 100G
T-450 or T-450 SWD
60G to 200G
T-600
60G to 100G
T-650
60G to 200G
T-750 or T-750 SWD
60G to 200G
T-900
60G to 100G
T-950
60G to 200G
T-1200
60G to 100G
T-1450
60G to 200G
* T-300 Model (Lower Extract) has a maximum final spin speed of 90G.
Programming 90 or 100G will both result in a spin speed of 90G. 60, 70 & 80G
settings will operate as programmed.
** T-350/T-350SWD Models (Lower Extract) have a maximum final spin speed of
180G. Programming 180 or 200G will both result in a spin speed of 180G. 60,
80, 100, 120, 140 & 160G settings will operate as programmed.
Summary of Contents for T-300 VENDED
Page 4: ...8514 302 001 REV B page 4...
Page 5: ...8514 302 001 REV B page 5...
Page 6: ...8514 302 001 REV B page 6...
Page 31: ...8514 302 001 REV B page 31 The figure below shows the sub menu options for Cycles...
Page 34: ...8514 302 001 REV B page 34 The figure below shows the sub menu options for Plus Cycle Options...
Page 37: ...8514 302 001 REV B page 37 The figure below shows the sub menu options for Settings...
Page 39: ...8514 302 001 REV B page 39 The figure below shows the sub menu options for Usage...