![Dexter Laundry T-300 VENDED Operators Manual Installation & Operation Instructions Download Page 27](http://html1.mh-extra.com/html/dexter-laundry/t-300-vended/t-300-vended_operators-manual-installation-and-operation-instructions_2490398027.webp)
8514-302-001 REV B page 27
Optional Cycles Option:
This option allows the user to select the different test and short-cycle options.
1. “Quick Test” will begin a shortened wash cycle without the displayed vend price
being met. The purpose of this shortened cycle is to test all major components for
proper operation.
Error Codes should all function normally during this test. The display will show
customer prompts in a similar way to a normal wash cycle. Exceptions to this are
that the “ADD BLEACH” prompt will not occur because of reduced cycle time. Final
Extract speed is specific to the customer’s programming.
2. “Rapid Advance” is similar to Quick Test, in that when this option is chosen, the
washer will begin a wash cycle without the displayed vend price being met.
However, in this case, it will be a normal default cycle with an additional feature
available. The “Start” button LED will flash, prompting the user that, when
pressed, the washer shall rapid advance to the next step in the cycle. The display
will show “ADVANCE” when the cycle is advancing. The water level needs to be
empty before this advance occurs. During the time waiting for the tub to empty,
the “ADVANCE” prompt will be held on the display and the start pushbutton LED
stops flashing. The Rapid Advance shall allow the tub to empty of water and the
tub to stop before beginning either spin or the next bath.
The Rapid Advance mode can be exited by pressing the programming button. This
will end the cycle. When the Rapid Advance mode is used, the cycle time will no
longer be correct. By skipping steps with Rapid Advance, the door may not open
immediately at the end of the cycle.
3. “Final Rinse and Spin” will begin only the Final Rinse Bath and Final Spin
portions of the cycle without the displayed vend price being met. The configured
temperature, cycle times, and spin speed for the Final Rinse Bath and Final Spin
settings will be used when this option is selected. Error Codes should all function
normally during this test.
Summary of Contents for T-300 VENDED
Page 4: ...8514 302 001 REV B page 4...
Page 5: ...8514 302 001 REV B page 5...
Page 6: ...8514 302 001 REV B page 6...
Page 31: ...8514 302 001 REV B page 31 The figure below shows the sub menu options for Cycles...
Page 34: ...8514 302 001 REV B page 34 The figure below shows the sub menu options for Plus Cycle Options...
Page 37: ...8514 302 001 REV B page 37 The figure below shows the sub menu options for Settings...
Page 39: ...8514 302 001 REV B page 39 The figure below shows the sub menu options for Usage...