4. Technical data

 

4.1 DX1 series  

Model 

1000E 

1000/H 

1030E 

1030/H 

Max. length (mm) 

1950 

1950 

1950 

1950 

Width (mm) 

700 

700 

700 

700 

Head part length (mm) 

550 

550 

750 

750 

Middle part length (mm) 

Foot part length (mm) 

1400 

1400 

1200 

1200 

Weight (approx., depending on 
equipment) kg 

80 

80 

85 

85 

Min. 

– max. height (mm) 

480 to 920 * 

470 to 920 * 

520 to 960 * 

510 to 960 * 

Adjustment time (motor) (s) 

22 

22 

Head part adjustment range  

+40° / -35° 

+40° / -35° 

0° / +75° 

0° / +75° 

Foot part adjustment range 

3-sectioned head part adjustment 
range 

+45° / -25° 

+45° / -25° 

Max. patient weight (kg) 

225 

225 

225 

225 

 
 

Model 

1050E 

1050/H 

Max. length (mm) 

1950 

1950 

Width (mm) 

700 

700 

Head part length (mm) 

550 

550 

Middle part length (mm) 

480 

480 

Foot part length (mm) 

920 

920 

Weight (approx., depending on equipment) kg 

90 

90 

Min. 

– max. height (mm) 

500 to 940 * 

490 to 940 * 

Adjustment time (motor) (s) 

22 

Head part adjustment range  

+40° / -30° 

+40° / -30° 

Foot part adjustment range 

   0° / + 50° 

  0° / + 50° 

3-sectioned head part adjustment range 

45° / -25° 

 +45° / -25° 

Max. patient weight (kg) 

225 

225 

 
 
 

Model 

1090/H 

1093/H 

1095/H 

Length (mm) 

 

1950

 

1950 

1950

 

Width (mm) 

700 

700 

700 

Head part length (mm) 

550 

750 

550 

Middle part length (mm) 

480 

Foot part length (mm) 

1400 

1200 

920 

Overall length (mm)  

2060 

2060 

2060 

Overall width (mm) 

780 

780 

780 

Weight (approx., depending on equipment) kg 

100 

105 

110 

Min. 

– max. height (mm) 

500 to 950 

540 to 990 

520 to 970 

Head part adjustment range  

0° / + 65° 

0° / +75° 

0° / + 65° 

Foot part adjustment range 

0° / + 50° 

Max. patient weight (kg) 

225 

225 

225 

        

Technical data subject to change

 

       *

for movability art. no.046: Height plus 20 mm

                               

         for movability art. no. 040N: Height minus 10 mm 
 

Summary of Contents for 1000/H

Page 1: ...pliers guarantees years of trouble free operation provided the device is handled correctly and as intended in accordance with the conditions described in the user manual In the unlikely event you need...

Page 2: ...al number 5 2 Operating manual 6 2 1 Table design 6 2 2 Height adjustment 6 2 3 Upholstery adjustment 6 2 4 Movability model dependent or optional 7 2 5 Additional equipment 7 3 Additional accessories...

Page 3: ...ing the device We recommend that you keep these instructions for use near the device for future reference The device may only be used by authorised instructed and competent persons who are sufficientl...

Page 4: ...level flat and solid surface Before use activate the brakes on the castors and make sure they are working properly 1 6 Commissioning The device is ready for use upon delivery Remove the power cable fr...

Page 5: ...nly take hold of the underframe NOT the upper frame 1 8 Model designation and type labelling The exact model designation depends on the choice of frame colour 00 white powder coated RAL 9010 03 white...

Page 6: ...ss the switch rail down the table is lifted Lift the switch rail up the table is lowered Here too brief activation double tap must take place beforehand see section 7 Alternatively the switch rails ca...

Page 7: ...table feet all four castors are activated simultaneously The following moving options exist Stage 1 The castors of the table are locked and can neither be moved nor rotated Stage 2 centre position The...

Page 8: ...de guard with the necessary caution Never operate the side guard if the hands fingers etc of another person are located between the bars or on the mechanism of the side guard Risk of being crushed pin...

Page 9: ...dle part length mm 480 480 Foot part length mm 920 920 Weight approx depending on equipment kg 90 90 Min max height mm 500 to 940 490 to 940 Adjustment time motor s 22 Head part adjustment range 40 30...

Page 10: ...ion 3 7 A Protection class II protective insulation connecting cable without protective conductor Protection rating IPX4 resistant to water splashes Degree of protection B The motor is maintenance fre...

Page 11: ...nt block the foot levers The power plug must not come into contact with water or cleaning agents The electrical components must not display any external damage through which liquid could enter Do not...

Page 12: ...use Both can be replaced without too much effort Please request the corresponding installation diagram if required Replacement parts can be obtained directly from Dewert 7 Safety devices Tables with...

Page 13: ...ckaging Safety notice Pay attention to sharp edges and pointed objects during disposal The packaging materials produced are mainly o Cardboard Paper o Plastic o Wood when delivered on a pallet Please...

Page 14: ...ith the options of movability not wheel lifting fixing mechanism side guards and push handle the intended purpose of the table is extended and also provides for the ideal positioning of patients for t...

Page 15: ...damaged All switches and supply lines undamaged Function check With electromotive adjustment Move all motors with the foot switch or the hand switch to both limit positions until automatic switch off...

Page 16: ...ssories Accessories such as belts belt pads belt guides paper roll holders armrests etc undamaged and is proper and secure fixing function possible All necessary toggle screws present Possible movabil...

Reviews: